ADT7420 Analog Devices, ADT7420 Datasheet - Page 15

no-image

ADT7420

Manufacturer Part Number
ADT7420
Description
16-Bit Digital I2C Temperature Sensor
Manufacturer
Analog Devices
Datasheet
Preliminary Technical Data
T
The T
the overtemperature limit value. An overtemperature event
occurs when the temperature value stored in the temperature
value register exceeds the value stored in this register. The INT
pin is activated if an overtemperature event occurs. The temper-
ature is stored in twos complement format with the MSB being
the temperature sign bit.
When reading from this register, the eight MSBs (Bit 15 to Bit 8)
are read first from Register Address 0x04 and then the eight
LSBs (Bit 7 to Bit 0) are read from Register Address 0x05. Only
Register Address 0x04 (T
into the address pointer register because the address pointer
autoincrements to Register Address 0x05 (T
The default setting for the T
T
The T
the undertemperature limit value. An undertemperature event
occurs when the temperature value stored in the temperature
value register is less than the value stored in this register. The
INT pin is activated if an undertemperature event occurs. The
temperature is stored in twos complement format with the MSB
being the temperature sign bit.
Table 12. T
Bit
[15:8]
Table 13. T
Bit
[7:0]
Table 14. T
Bit
[15:8]
Table 15. T
Bit
[7:0]
Table 16. T
Bit
[15:8]
Table 17. T
Bit
[7:0]
HIGH
LOW
SETPOINT REGISTERS
HIGH
LOW
SETPOINT REGISTERS
setpoint MSB and T
setpoint MSB and T
HIGH
HIGH
LOW
LOW
CRIT
CRIT
Default Value
0x49
Default Value
0x05
Default Value
0x80
Default Value
0x20
Default Value
0x00
Default Value
0x00
Setpoint MSB Register (Register Address 0x06)
Setpoint LSB Register (Register Address 0x07)
Setpoint MSB Register (Register Address 0x08)
Setpoint LSB Register (Register Address 0x09)
Setpoint MSB Register (Register Address 0x04)
Setpoint LSB Register (Register Address 0x05)
HIGH
HIGH
setpoint MSB) needs to be loaded
LOW
HIGH
setpoint is 64°C.
Type
R/W
Type
R/W
Type
R/W
Type
R/W
Type
R/W
Type
R/W
setpoint LSB registers store
setpoint LSB registers store
Name
T
Name
T
Name
T
Name
T
Name
T
Name
T
LOW
CRIT
CRIT
HIGH
LOW
HIGH
HIGH
MSB
MSB
LSB
LSB
MSB
LSB
setpoint LSB).
Description
LSBs of the critical overtemperature limit, stored in twos complement format.
Description
MSBs of the overtemperature limit, stored in twos complement format.
Description
LSBs of the overtemperature limit, stored in twos complement format.
Description
MSBs of the critical overtemperature limit, stored in twos complement format.
Description
LSBs of the undertemperature limit, stored in twos complement format.
Description
MSBs of the undertemperature limit, stored in twos complement format.
Rev. PrA | Page 15 of
When reading from this register, the eight MSBs (Bit 15 to
Bit 8) are read first from Register Address 0x06 and then the
eight LSBs (Bit 7 to Bit 0) are read from Register Address 0x07.
Only Register Address 0x06 (TLOW setpoint MSB) needs to be
loaded into the address pointer register as the address pointer
autoincrements to Register Address 0x07 (T
The default setting for the T
T
The T
the critical overtemperature limit value. A critical overtempe-
rature event occurs when the temperature value stored in the
temperature value register exceeds the value stored in this
register. The CT pin is activated if a critical overtemperature
event occurs. The temperature is stored in twos complement
format with the MSB being the temperature sign bit.
When reading from this register, the eight MSBs (Bit 15 to Bit 8)
are read first from Register Address 0x08 and then the eight
LSBs (Bit 7 to Bit 0) are read from Register Address 0x09. Only
Register Address 0x08 (T
into the address pointer register because the address pointer
autoincrements to Register Address 0x09 (T
The default setting for the T
CRIT
SETPOINT REGISTERS
CRIT
setpoint MSB and T
CRIT
CRIT
LOW
setpoint MSB) needs to be loaded
CRIT
limit is 147°C.
setpoint is 10°C.
setpoint LSB registers store
www.DataSheet4U.com
LOW
CRIT
setpoint LSB).
setpoint LSB).
ADT7420

Related parts for ADT7420