WT30-FT011 Omron Electronics Inc-IA Div, WT30-FT011 Datasheet

no-image

WT30-FT011

Manufacturer Part Number
WT30-FT011
Description
Specifications: Lead Free Status: Lead Free ; RoHS Status: RoHS Compliant
Manufacturer
Omron Electronics Inc-IA Div
Datasheet
Construct a Wireless System for ON/OFF
Data Collection That Is Ideal for Monitoring
Production Site Equipment
• Wireless Slave Station equipped with I/O.
• Height of 90 mm and DIN Rail mounting enables installation in
• Easily check wireless communications status from indicator
• I/O Slave Stations can also be used as Slave Stations in WD30
• Conforms to radio wave standards for Japan, China (pending),
Ordering Information
■ List of Models
Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal.
■ Accessories
Antennas
Communications Cables
Other
WT30-M01-FLK
WT30-SID16
WT30-SMD16
WT30-SMD16-1
WT30-AT001
WT30-AT002
WT30-AT003
XW2Z-0100U-3
XW2Z-0200U-3
XW2Z-0500U-3
XW2Z-0200U-5
XW2Z-0500U-5
WT30-FT001
WT30-FT002
WT30-FT003
WT30-FT011
WT30-CA2M
control panels.
display.
systems.
USA, and Europe.
FA Wireless SS Terminals
WT30
Wireless Unit model
Model
Model
Model
Magnet-base Antenna (2 antennas per set)
Flat Diversity Antenna (1 antenna)
Pencil Antenna (2 antennas per set)
1 m
2 m
5 m
2 m
5 m
DIN Rail Mounting Bracket (for TH35-7.5)
DIN Rail Mounting Bracket (for TH35-15)
Surface Mounting Bracket (screw-mounting)
(2 brackets per set)
Flat Diversity Antenna Mounting Brackets
(with magnets)
Antenna Extension Cable (1 cable, 2 m)
Length
Serial master
I/O slaves
For personal computer
Cross cable for PLC
Type
Type
Application
Type
16 DC inputs (NPN/PNP)
8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)
8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)
RS-232C
Applicable Standards
• FCC part 15.247 (USA)
• EN 300 440-2 (Europe)
• ARIB STD-T66 (Japan)
Main Class 2 Power Supplies
OMRON Switching Power Supplies
• S8VS (15 W, 30 W, 60 W type)
• S82K (15 W, 30 W, 50 W, 90 W type)
Applicable Countries
Wireless standards have been met for the following countries. The
product cannot be used in any other countries.
Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy,
Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland,
UK, USA
Always use a Class 2 power supply to conform to UL standards.
Use a DC power line less than 3 m to conform to EN standards. If a
power line of 3 m or longer is required, extend the length at the
Switching Power Supply’s primary side (i.e., the AC power line).
Conformity to Safety Standards
FA Wireless SS Terminals
Conformity to EN Standards
Specifications/No. of I/O points
(China) (approval pending)
WT30
1

Related parts for WT30-FT011

WT30-FT011 Summary of contents

Page 1

... Type WT30-FT001 DIN Rail Mounting Bracket (for TH35-7.5) WT30-FT002 DIN Rail Mounting Bracket (for TH35-15) WT30-FT003 Surface Mounting Bracket (screw-mounting) (2 brackets per set) WT30-FT011 Flat Diversity Antenna Mounting Brackets (with magnets) WT30-CA2M Antenna Extension Cable (1 cable Type Specifications/No. of I/O points RS-232C ...

Page 2

... Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent) Serial Safety standards Weight Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup. 2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration. ■ Wireless Interface Specifications Item Wave type Communication method ...

Page 3

... Make the detailed settings TEST, and SET mode. for RUN/TEST/SET mode. RS-232C Terminal Power supply terminal Connect the PLC, personal computer, etc. Supply power to the WT30. Serial communications setting switch Set the baud rate. ■ I/O Slave Station Node setting switch (WNODE) Set the unit number of the I/O Slave Station ...

Page 4

... WS (Wireless Status) Note: When using the WD30 as the Serial Master Station, the ERR indicator will light if normal I/O communications are not possible due to an error in the host network. WT30 Color Status Meaning (primary error) Green Lit Power is being supplied. Not lit Power is not being supplied ...

Page 5

... Error output (NPN) Input voltage Allowable voltage Max. switching current Error output Leakage (PNP) current Residual 6 7 COM ERRP voltage Fuse 6 7 COM ERRN Error output (NPN) D-sub, 9-pin, Female End at WT30 Pin No. Signal 1 --- --- 2 RD Output 3 SD Input 4 --- --- 5 SG --- 6 --- --- 7 --- ...

Page 6

... Output Circuit Diagram (NPN COM (IN) Output Circuit Diagram (PNP) V ERRP ERRN G I/O Slave Station WT30-SID16 WT30-SMD16 WT30-SMD16-1 13.3 WT30 V OUT 0 OUT 1 Fuse OUT 2 Fuse OUT 7 Fuse G Fuse V OUT 0 OUT 1 Fuse OUT 2 OUT 3 OUT 7 G 105 90 DIN rail mounting bracket WT30-FT001 or WT30-FT002 7.3 ...

Page 7

... Flat Diversity Antenna WT30-AT002 57.5 Three, 3 dia. 26 57.5 52 2010 10.5 dia. Surface Mounting Bracket WT30-FT003 FA Wireless SS Terminals With Pencil Antenna WT30-AT003 150 (46) (46) Surface Mounting Bracket WT30-FT003 Pencil Antenna WT30-AT003 75 10.5 dia. Flat Diversity Antenna Mounting Brackets (with magnets) WT30-FT011 WT30 40 Serial Master Station 7 ...

Page 8

Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the ...

Page 9

Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron247.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply ...

Related keywords