RS100-5 Astrodyne Corporation, RS100-5 Datasheet - Page 2

no-image

RS100-5

Manufacturer Part Number
RS100-5
Description
100w Single Output Switching Power Supply
Manufacturer
Astrodyne Corporation
Datasheet
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation (Note 3)
Load Regulation (Note 4)
Voltage Tolerance (Note2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
DC Volt Adjust
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
Harmonic Current
1 0 0 W Singl e O ut put Sw i tch i n g Po we r S uppl y
WWW.ASTRODYNE.COM
90 ~ 264 VAC; 125~373 Volts(DC)
47-63 Hz
40Amps / 230VAC
2.5 Amps. @ 115VAC
1.5 Amps. @ 230VAC
< 2mAmps /240VAC
See Selection Chart
See Selection Chart
±0.5%
See Selection Chart
See Selection Chart
See Selection Chart
100mS/230VAC
18mS/115VAC
500ms, 20m/230VAC
1200mS, 30mS/115VAC
3.8 ~ 4.45Volt(DC): 3.3Volts(DC)
5.75 ~ 6.75Volt(DC): 5Volts(DC)
13.8 ~ 16.2Volt(DC): 12Volts(DC)
17.25 ~ 20.25Volt(DC): 15Volts(DC)
27.6~ 32.4Volt(DC): 24Volts(DC)
55.2~ 64.8Volt(DC): 48Volts(DC)
Hiccup mode, auto recov
110 ~ 150% rated output power
Hiccup mode, auto recov
See Selection Chart
UL60950-1,
TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022 (CISPR22)
Class B
Compliance to EN61000-3-2,-3
Efficiency
Isolation
EMS
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
PHYSICAL SPECIFICATIONS
Size
Weight
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regula-
tion.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 0% to 100% rated load.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
Millimeters
Inches
-40°C to +85°C, 10~95% RH
-25°C to +70°C (See Derate Curve)
±0.03% / °C (0-50°C)
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
260.8KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 5G10min./1cycle, period for
20~90% RH non cond
60min. each along X, Y, Z axes
74% (RS100-3.3)
77% (RS100-5)
81% (RS100-12)
82% (RS100-15)
84% (RS100-24)
84%(RS100-48)
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2, 3, 4, 5, 6, 8, 11;
ENV50204,EN61000-6-2(EN50082-2)
heavy Industry Level, Criteria A
159 x 97 x 38
6.26” x 3.81 ” x 1.50 ”
21.16 oz (600g)
R S 1 0 0
s e r i e s

Related parts for RS100-5