Datasheet
Charging Operation
The AAT3697 has four basic modes for the battery
charge cycle: pre-conditioning / trickle charge; con-
stant current / fast charge; constant voltage; and
end of charge (see Figure 1).
Battery Preconditioning
Before the start of charging, the AAT3697 checks
several conditions in order to assure a safe charging
environment. The input supply must be above the
minimum operating voltage, or under-voltage lockout
threshold (V
begin. Also, the cell temperature, as reported by a
thermistor connected to the TS pin from the battery,
must be within the proper window for safe charging.
When these conditions have been met and a battery
is connected to the BAT pin, the AAT3697 checks the
state of the battery. If the cell voltage is below the pre-
conditioning voltage threshold (V
control begins preconditioning the cell.
The battery preconditioning trickle charge current is
equal to the fast charge constant current divided by
10. For example, if the programmed fast charge
current is 1.5A, then the preconditioning mode
(trickle charge) current will be 150mA. Cell precon-
ditioning is a safety precaution for deeply dis-
charged battery cells and also aids in limiting power
dissipation in the pass transistor when the voltage
across the device is at the greatest potential.
Fast Charge / Constant Current Charging
Battery cell preconditioning continues until the volt-
age on the BAT pin exceeds the preconditioning
voltage threshold (V
begins the constant current fast charging phase.
10
UVLO
Charge Complete Voltage
), for the charging sequence to
Constant Current Mode
Termination Threshold
MIN
Regulated Current
Trickle Charge and
Voltage Threshold
Figure 1: Current vs. Voltage Profile During Charging Phases.
). At this point, the AAT3697
I = CC / 10
MIN
Preconditioning
Trickle Charge
), the charge
Phase
I = Max CC
2A Lithium-Ion/Polymer Battery Charger
Constant Current
Charge Phase
The fast charge constant current (I
programmed by the user via the R
AAT3697 remains in the constant current charge
mode until the battery reaches the voltage regula-
tion point, V
Constant Voltage Charging
The system transitions to a constant voltage charg-
ing mode when the battery voltage reaches the
output charge regulation threshold (V
ing the constant current fast charge phase. The
regulation voltage level is factory programmed to
4.2V (±1%). Charge current in the constant voltage
mode drops as the battery cell under charge reach-
es its maximum capacity.
End of Charge Cycle Termination and Recharge
Sequence
When the charge current drops to 7.5% of the pro-
grammed fast charge current level in the constant
voltage mode, the device terminates charging and
goes into a sleep state. The charger will remain in
a sleep state until the battery voltage decreases to
a level below the battery recharge voltage thresh-
old (V
When the input supply is disconnected, the charg-
er will automatically transition into a power-saving
sleep mode. Only consuming an ultra-low 0.3μA in
sleep mode, the AAT3697 minimizes battery drain
when it is not charging. This feature is particularly
useful in applications where the input supply level
may fall below the battery charge or under-voltage
lockout level. In such cases where the AAT3697
input voltage drops, the device will enter sleep
mode and automatically resume charging once the
input supply has recovered from the fault condition.
RCH
).
BAT_EOC
Constant Voltage
Charge Phase
.
AAT3697
SET
CH
) amplitude is
resistor. The
3697.2007.02.1.1
BAT_EOC
) dur-

Related parts for AAT3697IWP-4.2-T1