MAS9138 MAS, MAS9138 Datasheet - Page 3

no-image

MAS9138

Manufacturer Part Number
MAS9138
Description
ASYNCHRONOUS TO SYNCHRONOUS CONVERTER
Manufacturer
MAS
Datasheet
PIN DESCRIPTION
ABSOLUTE MAXIMUM RATINGS
Parameter
Supply Voltage
Storage Temperature
RECOMMEDED OPERATION CONDITIONS
Parameter
Supply Voltage
Supply current
Operating Temperature
Pin name
XASY
XHST
RDO
TDO
RXC
VDD
RDI
TDI
PDIP
10
11
12
13
14
15
16
9
Pin no.
SO
10
11
12
13
14
15
16
9
Symbol
Symbol
I/O
VDD
VDD
IDD
O
O
P
I
I
I
I
I
Ts
Ta
Function
Transmitter data input. 1 = mark or stop bit. 0 = space, start or break
signal.
Transmitter data output. Output data is synchronized to the
synchronous timing signal TXC (pin 4). 1 = mark. 0 = space.
Asynchronous mode. XASY = 0 Asynchronous transmission, XASY = 1
Synchronous transmission. In synchronous transmission the converter
is totally bypassed in both directions: TDI = TDO, RDI = RDO
Higher speed signalling timing. XHST = 1 normal synchronous to
asynchronous conversion (CCITT V.14). XHST = 0 asynchronous to
synchronous conversion with higher speed synchronous timing (TXC,
RXC). TXC and RXC timing must be 1-2% higher than the normal bit
rate in order to allow some overspeed in the asynchronous data.
On the receiver side the RX buffer is deleted and the synchronous
data RDI is directly connected to the asynchronous output RDO.
Receiver data output. RDO is the received data converted back to
asynchrnous mode.
1 = mark or stop bit, 0 = space, start or break signal
Receiver data input. 1 = mark, 0 = space. The received data must be
synchronized to the receiver timing RXC from the synchronous
channel (pin 15).
Receiver timing (MAS9138 only). Receiver square wave timing from
the synchronous channel. The received data RDI must be
synchronized to the rising edge of RXC.
Power supply
Conditions
VDD = 5V
Conditions
Min
-40
3
2
Min
-0.5
-55
3.3 to
Typ
5.0
12 April, 2006
+150
Max
5.5
DA9138.005
Max
5.25
+85
5
3 (10)
(GND = 0V)
Unit
Unit
mA
o
o
V
V
C
C

Related parts for MAS9138