S20S300A Tamura Corporation Of America, S20S300A Datasheet

no-image

S20S300A

Manufacturer Part Number
S20S300A
Description
Hall Effect Current Sensors 100 To 300 Amp Applications ?? Closed Loop
Manufacturer
Tamura Corporation Of America
Datasheet
1
2
3
Hysteresis Allowance If=0 - Ifmax)
Specifications Measured at 25˚C, RL-10K , VCC=+15V
Output Temperature Characteristic
Package & Weight Information
Offset Temperature Characteristic
Insulation Resistance @ 500VDC
Without Offset
Ifmax is Restricted by Vcc
Output Current not included
Withstand Voltage (50/60Hz)
Nominal Primary DC Current
Frequency Bandwidth (-3dB)
Secondary Coil Resistance
QTY/Box
Output Linearity
Operating Temperature
Offset Current (If=0)
Current Consumption
Storage Temperature
Output Current @ If
50
Maximum Current
Conversion Ratio
Response Time
Power Supply
Fax: 909-676-9482
Tel: 800-872-6624
Accuracy
100 to 300 Amp Applications –– Closed Loop
Weight/each(g)
1
43352 Business Park Drive. | P.O. Box 892230 Temecula, CA 92589-2230 | www.tamuracorp.com
USA
Specification
(0..If)
25
1
If
TCI
(If)
I
Vcc
(max)
K n
I
R
OUT
Io
I
V
T
Rs
X
E
Ic
T
t
OT
OH
f
Hall Effect Current Sensors
r
IS
A
S
L
OUT
d
Fax: 81 (0)3 3923-0230
Tel: 81 (0)3 3978-2111
S21Z100D15
1:2000
50mA
100A
150A
Japan
TA M U R A C O R P O R AT I O N
• PCB Mount Design
• Current Output type
• Very High Linearity
• ±15V Supply Voltage
• CE EN50178 (pending)
TBD Ohms @ Ta = 70°C (Contact Tamura for additional info)
S21Z150D15
2,500VACrms for 1 minute (sensing current 0.5mA)
1:2000
75mA
150A
225A
±0.025mA / °C @ If=0 (Ta=-5 to +70°C)
±0.025% / °C @ If=0 (Ta=-5 to +70°C)
Fax: 44 (0) 1380 731 702
Tel: 44 (0) 1380 731 700
United Kingdom
±0.25% of If
DC - 150kHz
-10 - +70°C
-20 - +85°C
±15V ±5%
±1% of If
±16mA
< 0.3mA
500M
±0.5mA
< 1µs
3
2
S21Z200D15
1:2000
100mA
200A
300A
Fax: 852-2341-9689
Tel: 852-2389-4321
Hong Kong
w w w. t a m u r a c o r p . c o m
S21Z300D15
150mA
1:2000
300A
450A
84

Related parts for S20S300A

S20S300A Summary of contents

Page 1

Hall Effect Current Sensors 100 to 300 Amp Applications –– Closed Loop Specifications Measured at 25˚C, RL-10K , VCC=+15V Specification Nominal Primary DC Current (If) Maximum Current If (max) Output Current @ If I OUT Conversion Ratio K n Accuracy ...

Page 2

... Ohms @ 70°C (Contact Tamura Tech Support Japan United Kingdom Tel: 81 (0)3 3978-2111 Tel: 44 (0) 1380 731 700 Fax: 81 (0)3 3923-0230 Fax: 44 (0) 1380 731 702 S20S200A S20S300A 200A 300A 300A 450A 100mA 150mA 1:2000 1:2000 2 ...

Page 3

Hall Effect Current Sensors Amp Applications –– Closed Loop Specifications Measured at 25˚C, RL-10K , Vcc=+5V Specification Nominal Primary r.m.s. Current (If) Maximum Current If (max) Offset Voltage (If=0) V REF Output Voltage V OUT Output Voltage ...

Related keywords