RP100-482533DS Recom International Power, RP100-482533DS Datasheet

no-image

RP100-482533DS

Manufacturer Part Number
RP100-482533DS
Description
POWERLINE - DC/DC - CONVERTER
Manufacturer
Recom International Power
Datasheet
www.recom-international.com
Features
Selection Guide
Specifications
Input Voltage Range
Input/Output Isolation
Continuous Output Power
Base-Plate Temperature
Output Voltage Adjustment
Short Circuit Protection
Under-Voltage Protection
Over-Voltage Protection
Transient Response
Frequency of Operation
Efficiency (at nominal input voltage, full load)
Remote Shutdown
Ripple and Noise (20MHz BW )
Line Regulation, HL-LL
Load regulation (100% to 10% full load)
Temperature Coefficient
Transient Response Recovery Time (25% load step change)
Transient Voltage Peak Deviation
Switching Frequency
Operating Temperature Range
Temperature Coefficient (over operating temperature range)
Case Temperature
Case Material
Dimensions
POWERLINE - DC/DC-Converter
H-Series, 100 Watt (Dual Isolated Outputs)
Part Number
RP100-483305DS
RP100-482505DS
RP100-482533DS
Independently Regul. 5V & 3.3V,
5V & 2.5V, or 3.3V & 2.5V Outp.
36–75 VDC Input (48V Nominal)
100W Continuous Ouput Power
Efficiency up to 84% (Typ.)
Remote On/Off Control
(typical at nominal input and 25°C unless otherwise noted)
48V Input Types
Output
V1
V2
V1
V2
V1
V2
Voltage
2.5DC
(VDC)
3.3
2.5
3.3
5
5
Output
Built-in EMI Suppression Filter
Fixed Operating Frequency
Under-Voltage Lockout
Over-Voltage Shutdown
Short Circuit Protection
1500 VDC I/O Isolation
Max.
(A)
1
0
1
0
1
0
Lockout activated at 34V–35.5V input, automatic recovery. With 2V-3V hysteresis (typ.)
CMOS and open-collector TTL compatible: ON = 2.4V to Vin max.; Off = 0.8V or less
August 2002
Current
Max.
(A)
20
25
20
25
20
25
5V output – shutdown at 6.5V, typ.; 3.3V output – shutdown at 3.9V typ.;
+100 max.: internal thermal shutdown circuit., automatic recovery
within 1% of the regulation hand with no more than 5% deviation
Tolerance
200%µ S recovery after half-load to full load step. Change to
Voltage
±1.0%
±1.5%
±1.0%
±1.5%
±1.0%
±1.5%
Output
2.5V output – shutdown at 3.2V, typ. Reset at Vin = 0V
Ripple &
(mVp-p)
Outputs V1 & V2 each adjustable by ±10%
Noise
100
100
100
100
100
100
-40ºC to +100ºC (base plate)
Regulation
57.91 x 60.96 x 12.70 mm
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
Line
36-75VDC (48V nom.)
1500 VDC, I/O, 1 Min.
Aluminium base plate
Automatic recovery
See table above
300kHz, fixed
300mV, max.
300kHz, typ.
Regulation
100W max.
±0.02%/ºC
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load
84% typ.
±0.02%
±0.2%
±0.5%
500µ s
100°C
PO 73

Related parts for RP100-482533DS

RP100-482533DS Summary of contents

Page 1

... Part Number Output Voltage (VDC) RP100-483305DS 3.3 RP100-482505DS 2.5 RP100-482533DS V1 3.3 V2 2.5DC Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range Input/Output Isolation Continuous Output Power Base-Plate Temperature Output Voltage Adjustment Short Circuit Protection Under-Voltage Protection Over-Voltage Protection ...

Page 2

POWERLINE - DC/DC-Converter H-Series, 100 Watt (Dual Isolated Outputs) Derating Graph Package Style and Pinning (mm) 35.56 15.24 60.96 50. 120 100 80 60 Natural Convection Cooling - 100 125 85 Ambient ...

Related keywords