ICM7226 Intersil Corporation, ICM7226 Datasheet - Page 12

no-image

ICM7226

Manufacturer Part Number
ICM7226
Description
8-Digit Multi-Function Frequency Counter/Timer
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICM7226AIJI
Manufacturer:
INMOSST
Quantity:
2
Part Number:
ICM7226AIJL
Manufacturer:
INTERSIL
Quantity:
600
Part Number:
ICM7226AIJL
Manufacturer:
INTERSIL
Quantity:
600
Part Number:
ICM7226AIJL
Quantity:
1
Part Number:
ICM7226AIJL
Manufacturer:
INTERS
Quantity:
164
Part Number:
ICM7226BIPL
Quantity:
19
Part Number:
ICM7226BIPL
Manufacturer:
HARRIS
Quantity:
20 000
Display Considerations
The display is multiplexed at a 500Hz rate with a digit time of
244 s. An interdigit blanking time of 6 s is used to prevent
display ghosting (faint display of data from previous digit
superimposed on the next digit). Leading zero blanking is
provided, which blanks the left hand zeroes after decimal
point or any non zero digits. Digits to the right of the decimal
point are always displayed. The leading zero blanking will be
disabled when the Main Counter overflows.
The lCM7226A is designed to drive common anode LED dis-
plays at peak current of 25mA/segment, using displays with
V
than 3mA under these conditions. The lCM7226B is designed
to drive common cathode displays at peak current of
15mA/segment using displays with V
tors can be added in series with the segment drivers to limit
the display current, if required. The Typical Performance
Curves show the digit and segment currents as a function of
output voltage for common anode and common cathode
drivers.
To increase the light output from the displays, V
increased to 6.0V. However, care should be taken to see that
maximum power and current ratings are not exceeded.
The SEGment and Digit outputs in both the ICM7226A and
ICM7226B are not directly compatible with either TTL or
FIGURE 16. MAXIMUM ACCURACY OF FREQUENCY AND
FIGURE 18. MAXIMUM ACCURACY FOR FREQUENCY RATIO MEASUREMENT DUE TO LIMITATION OF QUANTIZATION ERRORS
F
= 1.8V at 25mA. The average DC current will be greater
0
2
4
6
8
1
0.01s
10
10
0.1s
10 CYCLES
10s
2
3
1s
PERIOD MEASUREMENTS DUE TO LIMITATIONS
OF QUANTIZATION ERRORS
1 CYCLE
CYCLES
CYCLES
10
FREQUENCY (Hz)
10
FREQUENCY MEASURE
3
PERIOD MEASURE
f
OSC
F
= 1.8V at 15mA. Resis-
0
1
2
3
4
5
6
7
8
= 10MHz
1
10
10
5
ICM7226A, ICM7226B
DD
10
2
may be
10
10
7
3
9-26
f
A
10
CMOS logic. Therefore, level shifting with discrete transis-
tors may be required to use these outputs as logic signals.
External latching should be down on the leading edge of the
digit signal.
Accuracy
In a Universal Counter, crystal drift and quantization errors
cause errors. In frequency, period and time interval
modes, a signal derived from the oscillator is used in either
the Reference Counter or Main Counter, and in these
modes, an error in the oscillator frequency will cause an
identical error in the measurement. For instance, an oscilla-
tor temperature coefficient of 20ppm/
surement error of 20ppm/
In addition, there is a quantization error inherent in any digi-
tal measurement of 1 count. Clearly this error is reduced by
displaying more digits. In the frequency mode maximum
accuracy is obtained with high frequency inputs and in
period mode maximum accuracy is obtained with low fre-
quency inputs. As can be seen in Figure 16. In time interval
measurements there can be an error of 1 count per interval.
As a result there is the same inherent accuracy in all ranges
as shown in Figure 17. In frequency ratio measurement
can be more accurately obtained by averaging over more
cycles of INPUT B as shown in Figure 18.
FIGURE 17. MAXIMUM ACCURACY OF TIME INTERVAL
/f
4
B
0
1
2
3
4
5
6
7
8
10
1
5
1 CYCLE
10 CYCLES
10
10
2
3
CYCLES
CYCLES
10
MEASUREMENT DUE TO LIMITATIONS OF
QUANTIZATION ERRORS
10
RANGE
MAXIMUM TIME INTERVAL
6
10
10
FOR 10 INTERVALS
7
2
TIME INTERVAL ( s)
10
10
MAXIMUM TIME INTERVAL
FOR 10
o
C.
8
3
10
3
INTERVALS
4
10
o
C will cause a mea-
5
MAXIMUM TIME
INTERVAL FOR
10
2
10
INTERVALS
6
10
7
10
8

Related parts for ICM7226