pmk130s Astrodyne Corporation, pmk130s Datasheet - Page 2

no-image

pmk130s

Manufacturer Part Number
pmk130s
Description
130 Watt Open Frame And U-channel Power Supplies With Pfc
Manufacturer
Astrodyne Corporation
Datasheet
1 3 0 Wat t O pen Fr ame a n d U - Ch a n n e l Po wer S upplies with PFC
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
Input Current
Power Factor (cold start)
Leakage Current
OUTPUT SPECIFICATIONS
Voltage and Current
Minimum Load (Triples)
Maximum Output Power
Preset Accuracy (Note 7)
Line Regulation (Note 6)
Load Regulation (Note 5)
Ripple/Noise (Notes 1,2,8)
Turn On
Hold Up Time
Rise Time
Short Circuit Protection
Over Voltage Protection
Over Current Protection
Transient Response
Over Shoot/Under Shoot
GENERAL SPECIFICATIONS
Safety
Isolation (Note 3)
Insulation Resistance
EMI
Efficiency
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Note 4)
Storage Temperature
WWW.ASTRODYNE.COM
Classification:
90-264VAC
47 - 63 Hz
60A @ 230VAC Input
2.3~0.8A (90-264VAC)
PF > 0.96 @ 230VAC
<3.5mA @ 264VAC, 50Hz
See Selection Chart
0.1A /0.1A/ 0A (0A Singles)
130 Watts
1%
0.5% nom / 1% max
0.5% nom / 1% max Singles
2%/5%/5% max. Triples
See Selection Chart
<4S, typ.
20mS, typ.
30mS, typ.
Auto recovery
130% max., Auto recovery
150% max., Auto recovery
10mS
<10% of Nominal O/P VDC
UL/cUL60950-1, TUV: EN60950-1
CE: EN60601-1, EN60601-1:2001
CB: IEC60950-1
Class 1, 3-Pin (L, N FG)
4242VDC I/P - O/P
2828 VDC I/P - GND
707VDC O/P - GND
≥ 20MΩ (500VDC, 1S I/P-O/P)
CISPR EN55022 class B
See Selection Chart
-10°C to +70°C (See Derate Curve)
-25°C to +85°C
*
*
*
*
*
*
*
Relative Humidity
EMS
MTBF
Vibration
Drop Test
PHYSICAL SPECIFICATIONS
Size
Weight
NOTES:
1. All measurements should be made directly at the terminals of the
2. Ripple and Noise depend upon output voltage a specified per particu-
lar model.
3. Isolation for up to 1min duration.
4. Specified for free-air convection cooling.
5. Load regulation measured from 20% to full load.
6. Line regulation measured from 90 - 264VAC/100VAC minimum
7. Preset accuracy measured at nominal load, 120VAC input.
8. O/P oise measured directly at pins/terminals @ nominal load, 0uF by
Special EMC Notice: The end application shall provide an earth ground
connection for conducted & radiated emission performance. Astrodyne is
not liable for the end application without extra earth connection to
PMK130S Open Frame Power Supply.
power supply.
required for full load start.
pass and 47uF electrolytic, pk-pk@ 20MHz bandwidth.
Harmonics:
Fluctuations:
ESD:
EFT:
Surge:
CS:
Dips:
(Open Frame)
(U-Channel)
Open-Frame
U-Bracket
RS:
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
P M K 1 3 0
10 to +90%, non-cond
IEC61000-3-2 Class D
IEC61000-3-3
IEC61000-4-2, 6KV Contact, 8KV Air
IEC61000-4-3 FR: 80MHz-2.5GHz
Field Strength: 3V/M
IEC61000-4-4 2KV on AC Line
IEC61000-4-5 1KV (L-L);
2KV (L, N-PE)
IEC61000-4-6 3V (EMF)
IEC61000-4-11 95% 250CY,
70% 25CY, 40% 5CY, 5% 0.5CY
197,000 Hrs Singles
175,700 Triples to MIL-HDBK-217F
4G Peak, 50~500Hz, 3 Axes, 30
Test Height 70cm
76.2 x 127 x 30.48mm (3” x 5” x 1.2”)
115.6 x 80.5 x 28mm
(4.55” x 3.17” x 1.50”)
10.25 oz (291g)
13.38 oz (380g)
*
*
s e r i e s