tc103pi MORNSUN Science& Technology Ltd., tc103pi Datasheet

no-image

tc103pi

Manufacturer Part Number
tc103pi
Description
Programmable Rtd/thermocouple Temperature Signal Input Alarms
Manufacturer
MORNSUN Science& Technology Ltd.
Datasheet
DESCRIPTION
FEATURES
● Three-port isolation
● High accuracy (0.1% F.S.)
● High linearity (0.1% F.S.)
● Isolation voltage(2500VAC)
● Low temperature drift (35PPM/°C)
● Digital bus (485)
● Input / Output range programmable
● High reliability(MTBF>500,000 hours)
Programmable RTD/Thermocouple Temperature
Signal Input Alarms
TR103PI(RTD temperature signal input)
TC103PI(Thermocouple temperature signal input)
Fax:86-20-38601272
Http://www.mornsun-power.com
temperature signal input alarms, receiving
data from the scene of the 2-wire, 3-wire,
4-wire RTD signal or from the scene of the
thermocouple, mV signals, isolate and transmit
the signal to the control room PLC and DCS.
There is 2 channel relay alarm output to the
control room when the temperature is higher
or lower than the limit, the alarm method can
be set up normally open or normally closed
and
temperature alarm. The device also has a
RS485 digital bus interface. It is intelligent,
configure the scope range and the type of the
RTD/thermocouple by computer.
independent power supply, and are mutually
isolated among power supply, input and
output.
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
The copyright and authority for the interpretation of the products are reserved by Mornsun
(input, output and power supply)
Programmable
This
Field devices connected:
Two-Wire, three-wire, four-wire RTD;
Thermocouple, mV signals.
high
series
temperature
of
RTD
products
/
alarm
Thermocouple
require
or
low
an
Source
Output
Power
Input
PRODUCT PROGRAM
Note: The initial setting is TR103PI-00, TC103PI-00, users can choose the signal type and range, and also
can be self-programming.
ELECTRICAL CHARACTERISTICS
(Thermocouple
temperature
signal input)
temperature
signal input)
TX103PI-
TR103PI-
TC103PI-
Output Signal
(RTD
Thermocouple
Power supply
Power consumption
Power protection
Output Signal
Load
Output current and instructions of
super-range alarm
Output current and instructions of
input disconnection alarm
Alarm method setting:
Can be independently set to normally
open or normally closed and high
temperature alarm or low temperature
alarm (switch 2 is to set low temperature
alarm,
temperature alarm, the free combination
of 2,3-position toggle switch, to set
normally open or normally closed)
Nominal switching capacity of relay
Communication Interface
Communication protocol
RTD
switch
0
1
2
3
0
1
2
3
4
5
6
7
x
Signal type and range
Connection setting
Signal type and range
Cold junction compensation -25°C ~ +75°C
Compensation accuracy
3
x
0
1
is
to
Signal Type
Current
Current
Pt1000
Cu100
Pt100
Cu50
set
mV
R
S
K
B
E
T
J
high
-150~+1370°C
320~+1820°C
Specifications subject to change without notice.
-200~+850°C
-200~+250°C
-40~+1700°C
-40~+1700°C
-160~+390°C
TX103PI
-50~+150°C
-50~+150°C
-80~+900°C
-80~+700°C
-60~+60mV
I≥22mA, Light “O” ON
Lower limit alarm
18~36VDC
About 2.3W
Reverse protection
Refer to product program
Setting RTD connection by toggle switch 1,
Refer to product program
Every 20°C error of ±1°C
Refer to product program
≤500Ω (Output current = max.)
Upper limit alarm I≥21mA, Light “H” ON
refer to the table below
4~20mA
0~20mA
3A 277VAC, 3A 30VDC
RS485 Physical Bus Interface
MODBus
Switch
Switch
Range
3
1
2
Description
Connection
High temp.
Low temp.
Function
Function
(
alarm
alarm
Typ: 24VDC
Minimum range
A/0-2009
I≤3mA, Light “L” ON
(Current output: 4~20mA)
I=0mA, Light “L” ON
(Current output: 0~20mA)
600°C
600°C
120°C
100°C
100°C
780°C
500°C
10mV
20°C
20°C
20°C
20°C
Low temp.
alarm
normally
open
High temp.
alarm
normally
open
3-wire
ON
)
ON
Page 1 of 3
0.4°C/0.2%
0.4°C/0.2%
0.4°C/0.2%
0.4°C/0.2%
40µV/0.2%
3°C/0.2%
3°C/0.2%
1°C/0.2%
1°C/0.2%
1°C/0.2%
1°C/0.2%
1°C/0.2%
Accuracy
Low temp.
alarm
normally
closed
High temp.
alarm
normally
closed
4/2-wire
OFF
OFF

Related parts for tc103pi

tc103pi Summary of contents

Page 1

... Output Signal 1 Note: The initial setting is TR103PI-00, TC103PI-00, users can choose the signal type and range, and also can be self-programming. ELECTRICAL CHARACTERISTICS Power supply Power Power consumption Source Power protection Signal type and range RTD Connection setting ...

Page 2

... Field RS 485A RS 485B r TC103PI Field RS 485A RS 485B Pt1 (-) MV S ignal Thermoc ouple 1. 3-wire RTD temperature signal input, terminal 9 and 10 must be short connected, ensure the equal value of three wire resistance as possible as you can ...

Page 3

INSTALLATION DIN35mm standard rail installation: 1. Upside of the instrument card in the rail; 2. Push underside of the instrument into the rail. PACKAGING DIMENSION Unit: mm[inch] Tolerances: ±0.5mm The copyright and authority for the interpretation of the products are ...

Related keywords