ncb10-30gm40-n0-15m-pur Pepperl+Fuchs, ncb10-30gm40-n0-15m-pur Datasheet - Page 3

no-image

ncb10-30gm40-n0-15m-pur

Manufacturer Part Number
ncb10-30gm40-n0-15m-pur
Description
Inductive Sensor
Manufacturer
Pepperl+Fuchs
Subject to modifications without notice
Pepperl+Fuchs Group
www.pepperl-fuchs.com
ATEX 2G
Instruction
Device category 2G
Directive conformity
Standard conformity
CE symbol
Ex-identification
EC-Type Examination Certificate
Effective internal capacitance C
Effective internal inductance L
General
Installation, Comissioning
Maintenance
Special conditions
Highest permissible ambient temperature
Appropriate type
Protection from mechanical danger
Electrostatic charging
Inductive sensor
fa-info@us.pepperl-fuchs.com
USA: +1 330 486 0001
i
i
Germany: +49 621 776-4411
fa-info@pepperl-fuchs.com
Manual electrical apparatus for hazardous areas
for use in hazardous areas with gas, vapour and mist
94/9/EG
EN 60079-0:2006, EN 60079-11:2007
Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
¬ II 1G Ex ia IIC T6
PTB 00 ATEX 2048 X
NCB10-30GM...-N0...
≤ 105 nF ; a cable length of 10 m is considered.
≤ 100 µH ; a cable length of 10 m is considered.
The apparatus has to be operated according to the appropriate data in the data
sheet and in this instruction manual. The EC-Type Examination Certificate has to
be observed. The special conditions must be adhered to!
Directive 94/9/EG and hence also EC-Type Examination Certificates apply in gene-
ral only to the use of electrical apparatus under atmospheric conditions.
The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces
by the mentioned certification authority.
If the equipment is not used under atmospheric conditions, a reduction of the per-
missible minimum ignition energies may have to be taken into consideration.
The temperature ranges, according to temperature class, are given in the EC-Type
Examination Certificate.
Laws and/or regulations and standards governing the use or intended usage goal
must be observed. The intrinsic safety is only assured in connection with an appro-
priate related apparatus and according to the proof of intrinsic safety.
No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
When used in the temperature range below -20 °C the sensor should be protected
from knocks by the provision of an additional housing.
Electrostatic charges must be avoided on the mechanical housing components.
Dangerous electrostatic charges on the mechanical housing components can be
avoided by incorporating these in the equipotential bonding.
fa-info@sg.pepperl-fuchs.com
0102
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
NCB10-30GM40-N0-15M-PUR
3