ncb10-30gm40-z1-3g-3d Pepperl+Fuchs, ncb10-30gm40-z1-3g-3d Datasheet - Page 2

no-image

ncb10-30gm40-z1-3g-3d

Manufacturer Part Number
ncb10-30gm40-z1-3g-3d
Description
Inductive Sensor
Manufacturer
Pepperl+Fuchs
Datasheet
2
ATEX 3G (nA)
Instruction
Device category 3G (nA)
Directive conformity
Standard conformity
CE symbol
Ex-identification
General
Installation, Comissioning
Maintenance
Special conditions
Maximum operating current I
Maximum operating voltage U
Maximum permissible ambient tempera-
ture T
Protection from mechanical danger
Protection from UV light
Electrostatic charging
Protection of the connection cable
Inductive sensor
at U
at U
at U
Umax
Subject to modifications without notice
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Bmax
Bmax
Bmax
=60 V, I
=60 V, I
=60 V, I
L
L
L
=100 mA
=50 mA
=25 mA
L
Bmax
fa-info@us.pepperl-fuchs.com
USA: +1 330 486 0001
Manual electrical apparatus for hazardous areas
for use in hazardous areas with gas, vapour and mist
94/9/EG
EN 60079-0:2006, EN 60079-15:2005
Ignition protection category "n"
Use is restricted to the following stated conditions
¬ II 3G Ex nA IIC T6 X
The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed!
Laws and/or regulations and standards governing the use or intended usage goal must be observed.
No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
The maximum permissible load current must be restricted to the values given in the following list. High load currents and load
short-circuits are not permitted.
The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not per-
missible.
dependant of the load current I
Information can be taken from the following list.
53 °C (127.4 °F)
58 °C (136.4 °F)
61 °C (141.8 °F)
The sensor must not be exposed to ANY FORM of mechanical danger.
The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor
is used in internal areas.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the
mechanical housing components can be avoided by incorporating these in the equipotential bonding.
The connection cable must be prevented from being subjected to tension and torsional loading.
Germany: +49 621 776-4411
fa-info@pepperl-fuchs.com
L
and the max. operating voltage U
fa-info@sg.pepperl-fuchs.com
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Bmax.
NCB10-30GM40-Z1-3G-3D

Related parts for ncb10-30gm40-z1-3g-3d