tl8230a Honeywell International's Solid State Electronics Center (SSEC), tl8230a Datasheet

no-image

tl8230a

Manufacturer Part Number
tl8230a
Description
Programmable Thermostat
Manufacturer
Honeywell International's Solid State Electronics Center (SSEC)
Datasheet
Honeywell’s TL8230A programmable thermostat can be connected to an
electric heater to control the room temperature.
*
**
NOTE:
unobstructed.
Some thermostat configurations can be
modified via the switches on the back of the
control module.
Default (factory) settings are inside the gray cells.
a.
b.
TL8230A
Heating power **
Program button
On/Off switch *
Mode selection /
program exit
SW1
SW2
SW3
Appears when
the setpoint is
displayed
If you change the temperature display format, the preset buttons (
will return to their default settings.
Early Start functions in Automatic mode only. When this function is enabled, the
thermostat calculates the optimal time to start heating in order to obtain the desired
temperature by the set time. The thermostat re-assesses the start time daily based
on the previous day’s performance.
Program
clear button
Day and time
settings
#
Set the switch to Off to cut power to the heater. This will not affect the time and tem-
perature settings.
The thermostat displays the heater duty cycle required to maintain the desired tem-
perature. For example,
time.
To remove the control module from the power
base, loosen the captive screw underneath the
thermostat and pull the two components apart
as shown.
To install the control module onto the power
base, reverse the above procedure.
Display
% of duty cycle
Always keep the thermostat's vents clean and
Description
Assembly/Disassembly
Configuration
Temperature format
Functionality
Early Start
Time format
1 to 24% 25 to 49% 50 to 74% 75 to 99%
appears when the heater is activated 40 percent of the
Backlight button
b
a
12-hour
Disable
UP
°F
Preset temperature
icon
Temperature
preset buttons
Time and day display
Temperature display
Mode display
Period display
Temperature
adjustment
buttons
24-hour
,
Enable
DN
°C
and
100%
)
1.
2.
3.
Upon power-up, the thermostat is in manual mode (
actual temperature.
LO: The measured temperature is below 32°F (0°C).
HI: The measured temperature is above 122°F (50°C).
When the backlight button is pressed, the display illuminates for 5 seconds.
When either of the
onds.
Setpoint
The thermostat generally displays the actual temperature. To view the
setpoint, press one of the
setpoint will appear for the next 5 seconds.
To change the setpoint, press one of the
ature is displayed. To scroll faster, hold the button.
Preset buttons
The thermostat has 3 temperature preset buttons:
To use a preset temperature, press the appropriate button. The corresponding
icon
The following table shows the intended use and the default setting of each of
the preset buttons.
To store a preset temperature:
Icon
Press the Hour and Min buttons to set the time.
Press the Day button to set the day.
Heating is activated.
Comfort preset button
Economy preset button
Vacation preset button
Set the desired temperature using the
Press and hold the appropriate preset button until the corresponding
icon is displayed.
Press Mode/Ret to exit.
,
Power-up
Error Messages
Backlight
Temperature Setting
Comfort
(when at home)
Economy
(when asleep or away from home)
Vacation
(during prolonged absence)
or
will be displayed.
Intended use
buttons is pressed, the display illuminates for 10 sec-
buttons once or press the backlight button. The
69-1803
Programmable Thermostat
buttons until the desired temper-
Default setting
62°F (16.5°C)
70°F (21°C)
50°F (10°C)
buttons.
TL8230A
User Guide
3/5/05
) and displays the
New
1/2
4.
5.
6.
7.

Related parts for tl8230a

tl8230a Summary of contents

Page 1

... Description Honeywell’s TL8230A programmable thermostat can be connected to an electric heater to control the room temperature. On/Off switch * Appears when the setpoint is displayed Day and time settings Heating power ** Program button Program clear button Mode selection / program exit Backlight button * Set the switch to Off to cut power to the heater. This will not affect the time and tem- perature settings ...

Page 2

... Press Pgm to select another period, or press Day to select another day. Then repeat step 3. Press Mode/Ret to exit the programming mode. NOTE button is pressed for 60 seconds, the thermostat will automati- cally exit the programming mode. TL8230A Use the following grid to record the new schedule. 8. Period is , ...

Related keywords