TRUMPower
DESCRIPTION
The TMC200 series of AC-DC switching power supplies in a
package of 3 x 5 x 1.5 inches are capable of delivering 200
watts of continuous power at 5.3 CFM forced air cooling or
150 watts at convection cooling. The units are constructed on
a printed circuit board with a U-bracket for mechanical support
and heat sinking. A cover-and-fan assembly can be added
during manufacturing for 200 watt output. They are specially
designed for medical applications, but not for life-supporting
equipment. The units are certified also to IEC /EN /UL /CSA
60950-1 and suitable for data networking, computer and
telecommunication applications.
FEATURES
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
Touch current:
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
Transient response:
Fan power:
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
3 x 5 i n c h f o o t p r i n t w i t h 1 . 5 i n c h l o w p r o f i l e
1 0 0 - 2 4 0 VA C i n p u t w i t h a c t i v e P F C
L e s s t h a n 2 2 0 uA l e a k a g e c u r r e n t
M e e t E N 5 5 0 11 / 5 5 0 2 2 a n d F C C C l a s s B
P o w e r F a c t o r 0 . 9 8 t y p i c a l
S h o r t - c i r c u i t p r o t e c t i o n
P o w e r F a i l D e t e c t ( P F D ) s i g n a l
I n h i b i t - T T L h i g h t o d i s a b l e o u t p u t
C o m p l i a n t w i t h R o H S r e q u i r e m e n t s
E f f i c i e n c y g r e a t e r t h a n 8 7 %
Phone: 408-988-6616
90-264 VAC
47-63 Hz
2.5 A (rms) for 115 VAC
1.25 A (rms) for 230 VAC
220 µA max. @ 264 VAC, 63 Hz
100 µA max. @ 264 VAC, 63 Hz
See rating chart.
See rating chart.
1% peak to peak maximum
set at 112-140% of its nominal output
voltage
Output protected to short circuit conditions
All outputs ±0.04%/ºC maximum
Maximum excursion of 4% or better on all
models, recovering to 1% of final value
within 500 us after a 25% step load
change
12 V at 250 mA maximum
0º C to +70ºC
-40º C to +85ºC
5% to 95% non-condensing
Derate from 100% at +50º C linearly to
50% at +70ºC, applicable to convection
and forced-air cooling conditions
•
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Fax: 408-988-6622
Tumbler Technologies + TRUMPower
•
200 WATT MEDICAL & ITE POWER SUPPLIES
email: sales@trumpower.com
TMC200 SERIES
SAFETY STANDARD APPROVALS
GENERAL SPECIFICATIONS
Switching frequency:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
Withstand voltage:
MTBF:
EMC Performance
EN55011/EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
•
UL 60601-1, CSA C22.2 No. 601.1
File No. E178020
TÜV EN 60601-1
UL 60950-1, CSA C22.2 No. 60950-1
TÜV EN 60950-1
Website: www.TRUMPower.com
100 KHz (typical)
87% minimum on all models
10 ms minimum at 110 VAC
±0.5% maximum at full load
20 A @ 115 VAC or 40 A @ 230 VAC, at
25ºC cold start
4000 VAC from input to output,
1500 VAC from input to ground,
500 VAC from output to ground
350,000 hours at full load at 25ºC ambient,
calculated per MIL-HDBK-217F
Class B conducted, class B radiated
Class B conducted, class B radiated
Class B conducted, class B radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8 KV air and ±6 KV contact
Radiated immunity, 3 V/m
Fast transient/burst, ±2 KV
Surge, ±1 KV diff., ±2 KV com
Conducted immunity, 3 Vrms
Magnetic field immunity, 3 A/m
Voltage dip immunity, 30% reduction for 500
ms, 60% reduction for 100 ms, >95%
reduction for 10 ms
RoHS
(LVD)