tmc200 Tumbler Technologies + TRUMPower, tmc200 Datasheet

no-image

tmc200

Manufacturer Part Number
tmc200
Description
200 Watt Medical & Ite Power Supplies
Manufacturer
Tumbler Technologies + TRUMPower
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmc20040C
Manufacturer:
TMC
Quantity:
5
Part Number:
tmc2004OC
Manufacturer:
TMC
Quantity:
27
Part Number:
tmc2005-JT
Manufacturer:
SMSC
Quantity:
101
Part Number:
tmc2005-JT
Manufacturer:
Standard
Quantity:
500
Part Number:
tmc20080
Manufacturer:
HITACHIAIC
Quantity:
5 012
TRUMPower
DESCRIPTION
The TMC200 series of AC-DC switching power supplies in a
package of 3 x 5 x 1.5 inches are capable of delivering 200
watts of continuous power at 5.3 CFM forced air cooling or
150 watts at convection cooling. The units are constructed on
a printed circuit board with a U-bracket for mechanical support
and heat sinking. A cover-and-fan assembly can be added
during manufacturing for 200 watt output. They are specially
designed for medical applications, but not for life-supporting
equipment. The units are certified also to IEC /EN /UL /CSA
60950-1 and suitable for data networking, computer and
telecommunication applications.
FEATURES
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
Touch current:
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
Transient response:
Fan power:
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
3 x 5 i n c h f o o t p r i n t w i t h 1 . 5 i n c h l o w p r o f i l e
1 0 0 - 2 4 0 VA C i n p u t w i t h a c t i v e P F C
L e s s t h a n 2 2 0 uA l e a k a g e c u r r e n t
M e e t E N 5 5 0 11 / 5 5 0 2 2 a n d F C C C l a s s B
P o w e r F a c t o r 0 . 9 8 t y p i c a l
S h o r t - c i r c u i t p r o t e c t i o n
P o w e r F a i l D e t e c t ( P F D ) s i g n a l
I n h i b i t - T T L h i g h t o d i s a b l e o u t p u t
C o m p l i a n t w i t h R o H S r e q u i r e m e n t s
E f f i c i e n c y g r e a t e r t h a n 8 7 %
Phone: 408-988-6616
90-264 VAC
47-63 Hz
2.5 A (rms) for 115 VAC
1.25 A (rms) for 230 VAC
220 µA max. @ 264 VAC, 63 Hz
100 µA max. @ 264 VAC, 63 Hz
See rating chart.
See rating chart.
1% peak to peak maximum
set at 112-140% of its nominal output
voltage
Output protected to short circuit conditions
All outputs ±0.04%/ºC maximum
Maximum excursion of 4% or better on all
models, recovering to 1% of final value
within 500 us after a 25% step load
change
12 V at 250 mA maximum
0º C to +70ºC
-40º C to +85ºC
5% to 95% non-condensing
Derate from 100% at +50º C linearly to
50% at +70ºC, applicable to convection
and forced-air cooling conditions
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Fax: 408-988-6622
Tumbler Technologies + TRUMPower
200 WATT MEDICAL & ITE POWER SUPPLIES
email: sales@trumpower.com
TMC200 SERIES
SAFETY STANDARD APPROVALS
GENERAL SPECIFICATIONS
Switching frequency:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
Withstand voltage:
MTBF:
EMC Performance
EN55011/EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
UL 60601-1, CSA C22.2 No. 601.1
File No. E178020
TÜV EN 60601-1
UL 60950-1, CSA C22.2 No. 60950-1
TÜV EN 60950-1
Website: www.TRUMPower.com
100 KHz (typical)
87% minimum on all models
10 ms minimum at 110 VAC
±0.5% maximum at full load
20 A @ 115 VAC or 40 A @ 230 VAC, at
25ºC cold start
4000 VAC from input to output,
1500 VAC from input to ground,
500 VAC from output to ground
350,000 hours at full load at 25ºC ambient,
calculated per MIL-HDBK-217F
Class B conducted, class B radiated
Class B conducted, class B radiated
Class B conducted, class B radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8 KV air and ±6 KV contact
Radiated immunity, 3 V/m
Fast transient/burst, ±2 KV
Surge, ±1 KV diff., ±2 KV com
Conducted immunity, 3 Vrms
Magnetic field immunity, 3 A/m
Voltage dip immunity, 30% reduction for 500
ms, 60% reduction for 100 ms, >95%
reduction for 10 ms
RoHS
(LVD)

Related parts for tmc200

tmc200 Summary of contents

Page 1

... TRUMPower DESCRIPTION The TMC200 series of AC-DC switching power supplies in a package 1.5 inches are capable of delivering 200 watts of continuous power at 5.3 CFM forced air cooling or 150 watts at convection cooling. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking ...

Page 2

... TMC200-S48 NOTES: 1. U-bracket format is standard. Add suffix “C” for enclosed form with cover-and-fan assembly, e.g. TMC200-S24C 2. 150 W without moving air or 200 W with 5.3 CFM forced air provided by user for U-bracket format, 200 W for “C” version with cover-and-fan assembly 3. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with tantalum capacitor in parallel with a 0 ...

Page 3

... MODEL TMC200-S12 TMC200-S28 TMC200-S15 TMC200-S36 FAN +12V TMC200-S18 TMC200-S48 TMC200-S24 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 • Fax: 408-988-6622 TMC200 MEDICAL & ITE SERIES VOID LIVE VOID NEUTRAL RETURN ...

Related keywords