sgp1200-12g Power-One, sgp1200-12g Datasheet - Page 2

no-image

sgp1200-12g

Manufacturer Part Number
sgp1200-12g
Description
Ac-dc Front-end Data Sheet
Manufacturer
Power-One
Datasheet
Input Specifications
Output Specifications
1
BCD.00022_AA2, 01-Aug-10
The fan is considered to be part of the load.
AC Input Voltage
Input Frequency
Hold-up Time
Input Current
Inrush Surge Current
Power Factor
Efficiency
Minimum Load
Output Power
Overshoot
Transient Response
Turn-On Delay
with PS_ON signal
Output Regulation
Parameter
Parameter
1
Single-phase continuous input range.
AC input.
After last AC line peak at full power. At 120 VAC.
At full-rated load.
Excluding Xcap. Under all conditions.
Per EN61000-3-2; at 30% or higher load
110 VAC 70%FL
110 VAC 100% FL
230 VAC 70%FL
230 VAC 100% FL
Main Output 12V minimum loading required to
maintain regulation.
Note: Minimum starting load:
12V -> 9A, 3V3 -> 0.2A
Time required for initial output voltage
stabilization after application of AC input or
ON/OFF signal.
See Model Selection data on page 1.
Load Step of 50% Full load
Conditions/Description
Conditions/Description
SGP1200-12G AC-DC Front-End Data Sheet
Page 2 of 9
At 120 VAC.
Min.
86.5
84.5
87.5
0.5
> 0.95
89
Min.
90
47
12
12V Output, 1133 Watts
Nom.
87.5
85.5
Nom.
90
89
www.power-one.com
<3000
Max.
Max.
1133
264
<12
<30
63
<5
<5
Units
A rms
W/VA
Units
VAC
A pk
ms
ms
Hz
%
%
%
%
W
%
%
A

Related parts for sgp1200-12g