ap12-1-51-203-fm Sensata Technologies, ap12-1-51-203-fm Datasheet

no-image

ap12-1-51-203-fm

Manufacturer Part Number
ap12-1-51-203-fm
Description
Ap/up, Ap/mil Series Magnetic Circuit Protectors
Manufacturer
Sensata Technologies
Datasheet
Introduction
Single Pole
Multi-Pole
Configurations
Operating Characteristics
Delay Curves
Specifications
Decision Tables
|
|
|
|
|
|
|
|
68
69
70
72
73
74
75
76
AP/UP, AP/MIL Series
Magnetic Circuit Protectors

Related parts for ap12-1-51-203-fm

ap12-1-51-203-fm Summary of contents

Page 1

Introduction Single Pole Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables AP/UP, AP/MIL Series Magnetic Circuit Protectors ...

Page 2

INTRODUCTION The Airpax™ AP series are fully sealed, magnetic circuit protectors that combine power switching and accurate, reliable circuit protection with inverse time delays and trip free features. Unlike a thermal circuit protector, the AP does not change its trip ...

Page 3

Mounting Detail FOR PANEL INTEGRITY, THIS HOLE MUST BE BLIND WITH .075 [ 1.91 ] MIN. DEPTH . 325 .125 [ [ [ [ 3.18 8.26 . 391 [ [ 9.93 Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] Maximum ...

Page 4

... AP/UP, AP/MIL Series - Multi-Pole The AP12 consists of two independent series trip protectors, each available with its own rating and delay characteristics. This two pole unit can therefore have an unlimited number of combinations, which makes ordering by a code system impractical. Thus, if the poles differ, a descriptive drawing is recommended ...

Page 5

All multi-pole units have provisions for a rugged three point panel mount. Use of 6-32 panel seal screws together with the bushing mount is recommended ...

Page 6

CONFIGURATIONS Series Trip The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional ...

Page 7

OPERATIONAL CHARACTERISTICS Inrush Pulse Tolerance The following table provides a comparison of inrush pulse tolerance with and without the inertial delay feature for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of half sine wave ...

Page 8

TyPICAL DELAy CURvES The delay curves below illustrate our standard instant, short and long delays. Please consult factory for specific delay curves or refer to table on page 87. Delay curves 64 and 65 illustrate the improved inrush tolerance provided ...

Page 9

Trip free AP circuit protectors will trip open on overload, even when forcibly held ON. This prevents the operator from damaging the circuit by holding the handle in the ON position. Trip Indication The operating handle of the breaker moves ...

Page 10

... DC circuit. It has a short time delay and a rating of 20 amperes. The coding given permits a descriptive part number, with limitations. In the illustrated double pole example (AP12-1- 51-203 automatically assumed that both poles are identical. One great virtue of magnetic circuit protectors is their adaptability to complex circuits, thus variations from pole to pole become the rule rather than the exception ...

Page 11

... Shunt -4 Relay (5 amps max coil rating) Multi-pole units with mixed construction, poles numbered left to right when viewed from terminal end ( Note http://airpax.sensata.com/ Example: AP12 -1 -51-203- Fourth Decision Hz and Delay -40 400Hz 150% instant trip* ...

Page 12

...