iru3037acftr International Rectifier Corp., iru3037acftr Datasheet - Page 10

no-image

iru3037acftr

Manufacturer Part Number
iru3037acftr
Description
8 Pwm 200 Khz Sync Contr In A 8-pin Tssop Package
Manufacturer
International Rectifier Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IRU3037ACFTR
Manufacturer:
IR
Quantity:
2 351
IRU3037/IRU3037A & (PbF)
6) Place second pole at the ESR zero.
7) Place second zero around the resonant frequency.
8) Use equation (1) to calculate R
These design rules will give a crossover frequency ap-
proximately one-tenth of the switching frequency. The
higher the band width, the potentially faster the load tran-
sient speed. The gain margin will be large enough to
provide high DC-regulation accuracy (typically -5dB to -
12dB). The phase margin should be greater than 45) for
overall stability.
IC Quiescent Power Dissipation
Power dissipation for IC controller is a function of ap-
plied voltage, gate driver loads and switching frequency.
The IC's maximum power dissipation occurs when the
IC operating with single 12V supply voltage (Vcc=12V
and Vc 24V) at 400KHz switching frequency and maxi-
mum gate loads.
Figures 9 and 10 show voltage vs. current, when the
gate drivers loaded with 470pF, 1150pF and 1540pF ca-
pacitors. The IC's power dissipation results to an exces-
sive temperature rise. This should be considered when
using IRU3037A for such application.
Layout Consideration
The layout is very important when designing high fre-
quency switching converters. Layout will affect noise
pickup and can cause a good design to perform with
less than expected results.
10
F
R
Check if R
If R
F
R
R
P2
Z2
8
6
5
=
=
=
= F
8
= F
is too small, increase R
2π × C
V
2π × C
ESR
LC
OUT
V
REF
8
- V
>
1
10
1
REF
10
g
1
× F
m
× F
× R
Z2
P2
6
- R
8
7
and start from step 2.
5
.
www.irf.com
Start to place the power components, make all the con-
nection in the top layer with wide, copper filled areas.
The inductor, output capacitor and the MOSFET should
be close to each other as possible. This helps to reduce
the EMI radiated by the power traces due to the high
switching currents through them. Place input capacitor
directly to the drain of the high-side MOSFET, to reduce
the ESR replace the single input capacitor with two par-
allel units. The feedback part of the system should be
kept away from the inductor and other noise sources,
and be placed close to the IC. In multilayer PCB use
one layer as power ground plane and have a control cir-
cuit ground (analog ground), to which all signals are ref-
erenced. The goal is to localize the high current path to
a separate loop that does not interfere with the more
sensitive analog control function. These two grounds
must be connected together on the PC board layout at a
single point.
Figure 8 shows a suggested layout for the critical com-
ponents, based on the schematic on page 14.
PGnd
Vin
C1
D
3
Analog Gnd
D
2
D
1
L1
C
5
R4
Figure 8 - Suggested layout.
PGnd
C9
C4
C8
(Topside shown only)
5
6
7
8
8
1
IRU3037
C2A, B
7
2
U1
Q1
4
3
2
1
R5
C3
R6
6
3
PGnd
5
4
Analog Gnd
Single Point
Analog Gnd
Connect to
Power Ground plane
L2
C7A, B
PGnd
Vout

Related parts for iru3037acftr