b5975 EPCOS AG, b5975 Datasheet - Page 7

no-image

b5975

Manufacturer Part Number
b5975
Description
Ptc Inrush Current Limiters
Manufacturer
EPCOS AG
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
b59750B0120A070
Manufacturer:
LITTLEFUSE
Quantity:
42 000
Part Number:
b59750B0120A070
Manufacturer:
EPCOS
Quantity:
4 500
Part Number:
b59750T1120A062
Manufacturer:
EPCOS
Quantity:
56 000
Part Number:
b59750T1120A062
Manufacturer:
EPCOS
Quantity:
6 000
Part Number:
b59750T1120A062
Quantity:
20 500
Part Number:
b59751B0120A070
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Mounting
Operation
Please read Cautions and warnings and
Important notes at the end of this document.
Inrush current limiters
Leaded disks
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Page 7 of 10