tfs70h28 Vectron International, Inc., tfs70h28 Datasheet

no-image

tfs70h28

Manufacturer Part Number
tfs70h28
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
File name : TFS70H28.doc
VI TELEFILTER
1. Measurement condition
Ambient temperature T
Input power level:
Terminating impedances at f c * ) :
Source impedance:
Load impedance:
2. Characteristics
Remark:
Reference level for the relative attenuation a rel of the TFS 70H28 is the minimum of the pass band attenuation a min . The minimum of the pass
band attenuation a min is defined as the insertion loss a e . The reference frequency f c is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss a e . The temperature coefficient of frequency Tc
reference frequency f c and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme
Data
Insertion loss (Reference level)
Centre frequency at ambient temperature T
Pass band at ambient temperature T
Amplitude ripple (p-p):
Bandwidth
Relative attenuation :
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB (p-p):
Triple transit attenuation compared to main signal
Crosstalk
Substrate material
Frequency inversion temperature ( T
Temperature coefficient of frequency ( Tc
Frequency deviation of f c over temperature: ** )
Operating temperature range
Storage temperature range
*)
** ) f
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
20
40
45
f
f
f
The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
C
C
C
1
3
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
To
 1,25 MHz .... f
 2,45 MHz .... f
 4,45 MHz .... f
is reference frequency f c at frequency inversion temperature (T
dB
dB
dB
dB
dB
tft@telefilter.com
f
C
at ambient temperature:
.... f
A
:
Generated:
Checked/Approved:
C
C
C
C
 1,25 MHz
 1,50 MHz
 4,45 MHz
 30
f
C
..... f
MHz
A
:
o
23 C
0 dBm.
for input:
for output:
50
50
C
)
 1,20 MHz
f
A
)
a e
f c
PB
a rel
Filter specification
1275
953
o
)
f c (Hz) = Tc
- 8,93 pF.
- 7,32 pF.
20...40 C
-0,045
typical values
70,01 MHz
Quartz
0,35 dB
2,75 MHz
3,15 MHz
4,41 MHz
4,61 MHz
4,71 MHz
2,77 s
25 dB
50 ns
54
60
2,3
f
(ppm/K) x (T - T
-
-
-
-
ppm/K
Dunzow W.P.
Dr. Bert Wall
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail:
f
C
o
) x f
- 1,5 MHz ... f
vti@vtinh.com
Version 1.1
TFS 70H28
To
- 25 C ... + 80 C
- 40 C ... + 85 C
(MHz)
tolerance / limit
max.
max. 0,8 dB
min. 2,50 MHz
min. 3,00 MHz
max. 4,90 MHz
max.
max.
min.
min.
max. 4,0 s
max.
max.
70  0,09 MHz
C
+ 1,5 MHz
26 dB
40 dB
50 dB
90 ns
f
4
is valid both for the
1 dB
3 dB
04.02.2002
1/5

Related parts for tfs70h28

tfs70h28 Summary of contents

Page 1

... File name : TFS70H28.doc VI TELEFILTER 1. Measurement condition 23 C Ambient temperature Input power level: 0 dBm. Terminating impedances for input: for output: Source impedance: 50 Load impedance Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 70H28 is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min is defined as the insertion loss a e ...

Page 2

... File name : TFS70H28.doc VI TELEFILTER 3. Construction and pin connection 22,5 Max. 5,0 max. 5,6 max. 2,54  0,2 6x2,54 = 15,62 TFS 70H28 P22 matching networks ( see Application Note ) : For final test we use scheme 1. 1 Scheme Scheme 1 TELEFILTER ...

Page 3

... File name : TFS70H28.doc VI TELEFILTER 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...

Page 4

... File name : TFS70H28.doc VI TELEFILTER 6. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 C - 170 C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec ...

Page 5

... File name : TFS70H28.doc VI TELEFILTER 7. History Version Reason of Changes 1.0 Generate Filter specification. 1.1 - correct dimensions in  Construction and pin connection . VI TELEFILTER Potsdamer Stra 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application ...

Related keywords