atr11-c-y-63-r-8.0a ETC-unknow, atr11-c-y-63-r-8.0a Datasheet

no-image

atr11-c-y-63-r-8.0a

Manufacturer Part Number
atr11-c-y-63-r-8.0a
Description
Circuit Breaker Thermal Circuit Protector 1pole 1a 240vac 2-pin
Manufacturer
ETC-unknow
Datasheet
A
T
f
Specifications:
Airpax
Expands Of
Airpax, a global leader in the supply of
power protection products, has expanded its
offering to include the new ATR thermal circuit
protector for equipment. The ATR is a single
pole, thermally operated overload protector with a
snap-acting trip mechanism that provides reliable,
trip-free operation on current overloads.
The ATR comes with an unequaled 24-month warranty.
Please contact Airpax for assistance in applying the ATR
thermal circuit protector to meet your power protection needs.
Airpax
Expands Of
A
T
f
o
o
Current Ratings: 0.5A - 16A, Standard Ratings Available
Rated Voltage: 240 Vac, 50/60HZ, 32Vdc, 24Vdc (VDE)
Resettable Overload Capacity:
Operating Temperature: 60°C Max. Ambient
Max. Interrupting Capacity: 1000A
Insulation Resistance: >100 megohms
Dielectric Strength: 1.5 KV for 1 min. (per IEC 60934)
Operational Life: 1000 Cycles @ 2 x I n
Designed to meet: Shock: per MIL-STD-202, method 213,
h
T
h
T
r
r
e
e
R
R
E
E
r
r
m
m
q
q
u
u
a
a
i
i
l
l
p
p
C
C
m
m
test condition I
Vibration: per MIL-STD-202, method 204
test condition A
fering
fering
i
i
e
r
e
r
c
c
n
n
Warranty: 24 months from date of
u
u
t
t
manufacture, as marked on unit
Airpax Corporation
807 Woods Road
Cambridge, Maryland 21613 USA
Tel: 410.228.1500 Fax: 410.228.3456
i
i
t
t
8x I n for < 6A,
6x I n or 60A max. ≥ 6A
P
P
r
r
o
o
t
t
e
e
c
c
t
t
o
o
r
r
Application: Typical applications include power strips,
single-phase motors, transformers, solenoids, UPS, etc.
Operation: The trip mechanism of the circuit protector is
designed to open the contacts in the event of a current flow
in excess of the rated current and in accordance with the
time/current characteristics of the device. A bimetal strip
deflects and releases the latch mechanism when heated by
an overload. The strip has the advantage of being immune
to high inrush currents and line transients. The contacts
open and close with a positive snap action, and the tripped
state is clearly indicated by the protruding reset button.
Shunt Terminal (Option N): Available on units of up to 6
amps equipped with a heater winding, an optional additional
terminal can be provided as a parallel circuit to the main
current-sensing circuit. The shunt circuit between terminals
1 and 3 may be used for any signal that may be required in
addition to the main circuit. However, since the circuit makes
use of the bimetal strip as a current-carrying path, the trip
time of the circuit protector may be slightly influenced.
Time/Current Characteristics: The standard characteristic
is valid for an ambient temperature of 23°C. However, if the
device is to be used in an ambient temperature other than
23°C, an allowance must be made when selecting the
current rating. See the following guidelines:
Example:
Normal Continuous Current:
Ambient Temp.:
Multiplication Factor:
Recommended Rating:
Select the Nearest Rating:
Ambient Temperature Correction Factor
Ambient Temp.
Multiplication
1.8 A
40°C
1.12
1.8 x 1.12 = 2.016
2 A
Factor
Approvals:
Up to 16A
Up to 12A
R R
C C
R R
C C
(°C )
o o
o o
o o
o o
H H
m m
H H
m m
S S
S S
p p
p p
-20 -5
0.8 0.88 0.9 0.96
l l
l l
i i
i i
a a
a a
n n
n n
t t
t t
0
+10 +20 +30 +40 +50 +60
Operating Characteristics:
(min) 60
(S) 50
1
30
20
10
20
10
0.5
0.2
0.1
5
1
5
2
1
1.05 1.12 1.2
Multiple of Current Rating
1.05 1.32
Rated Current
Ambient
Temperature
2
1.3
3
4 5
< 6A
≥ 6A
23°C
(x I ) n
8 10

Related parts for atr11-c-y-63-r-8.0a

atr11-c-y-63-r-8.0a Summary of contents

Page 1

...

Page 2

... Terminal 7 .354 .394 9 10 .441 .335 11.2 8.5 1.18 30 .748 1.083 19 27.5 .295 .276 7.5 7 .032 .590 0.8 15 ATR11 - 7. Third Decision Terminal Configuration X Terminal 1 & Terminal 1 & Shunt Terminal PCB Knurled Nut: Protective Cover: P/N 053-000-0002 Dust/Splash (IP54) P/N 053-000-0001 .370 9.4 M10 x 1 ...