emc2105 Standard Microsystems Corp., emc2105 Datasheet - Page 42

no-image

emc2105

Manufacturer Part Number
emc2105
Description
Emc2105 Rpm-based High Side Fan Controller With Hardware Thermal Shutdown
Manufacturer
Standard Microsystems Corp.
Datasheet
Revision 1.74 (05-08-08)
ADDR
5Ch
5Dh
55h
56h
57h
58h
59h
5Ah
5Bh
5Eh
5Fh
60h
61h
62h
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LUT Temp 4
LUT Temp 1
LUT Temp 2
LUT Temp 3
LUT Temp 4
LUT Temp 1
LUT Temp 2
LUT Temp 3
LUT Temp 4
LUT Temp 1
LUT Temp 2
LUT Drive 2
LUT Drive 3
LUT Drive 4
REGISTER
Setting 1
Setting 2
Setting 2
Setting 2
Setting 2
Setting 3
Setting 3
Setting 3
Setting 3
Setting 4
Setting 4
NAME
Table 6.1 EMC2105 Register Set (continued)
Temp 2 temp) that is associated with the
External Diode 2 (or VIN2) channel that
temp) that is associated with the Drive 2
Temp 2 temp) that is associated with the
External Diode 1 (or VIN1) channel that
External Diode 2 (or VIN2) channel that
temp) that is associated with the Drive 3
Temp 2 temp) that is associated with the
External Diode 1 (or VIN1) channel that
External Diode 2 (or VIN2) channel that
External Diode 1 (or VIN1)channel that
TRIP_SET voltage or Pushed Temp 1
TRIP_SET voltage or Pushed Temp 1
External Diode 3 channel (or VIN3 or
External Diode 3 channel (or VIN3 or
Stores the second programmed drive
is associated with the Drive 2 value
is associated with the Drive 2 value
is associated with the Drive 3 value
is associated with the Drive 3 value
Stores the fourth programmed drive
is associated with the Drive 4 value
is associated with the Drive 4 value
Internal Diode channel (or Pushed
Internal Diode channel (or Pushed
Internal Diode channel (or Pushed
Stores the third programmed drive
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
DATASHEET
setting for the LUT
setting for the LUT
setting for the LUT
RPM-Based High Side Fan Controller with Hardware Thermal Shutdown
Drive 1 value
Drive 2 value
Drive 3 value
FUNCTION
42
value
value
DEFAULT
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
VALUE
BCh
E6h
D1h
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
LOCK
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
Lock
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
SMSC EMC2105
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Page 68
Datasheet
PAGE

Related parts for emc2105