cf48240qtc06nrs-g SynQor Worldwide Headquarters, cf48240qtc06nrs-g Datasheet
cf48240qtc06nrs-g
Related parts for cf48240qtc06nrs-g
cf48240qtc06nrs-g Summary of contents
Page 1
Continuous Input Transient Input Rated for CF Patient Contact and Defibrillation Proof The CFQor series of Quarter-Brick DC-DC converters is designed for those medical applications that require isolation and leakage current levels that comply with IEC60601-1 for CF ...
Page 2
CF48-QT Family Electrical Characteristics (all output voltages 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with appropriate power derating. Specifications subject to change without ...
Page 3
Family Electrical Charts (all output voltages) Nominal Vout Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/ OFF Pin 100,000 10,000.0 1,000.0 100.0 10 Increase in ...
Page 4
Technical Specification CF48050QTx25 Electrical Characteristics (5.0Vout 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with appropriate power derating. Specifications subject to change without notice. ...
Page 5
Technical Specification 100 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25° ...
Page 6
Technical Specification CF48120QTx12 Electrical Characteristics (12.0Vout 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with appropriate power derating. Specifications subject to change without notice. ...
Page 7
Technical Specification 100 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. ...
Page 8
Technical Specification CF48150QTx10 Electrical Characteristics (15.0Vout 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with appropriate power derating. Specifications subject to change without notice. ...
Page 9
Technical Specification 100 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 12 ...
Page 10
Technical Specification CF48240QTx06 Electrical Characteristics (24.0Vout 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with appropriate power derating. Specifications subject to change without notice. ...
Page 11
Technical Specification 100 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25° ...
Page 12
BASIC OPERATION AND FEATURES This converter series uses a two-stage power conversion topology. The first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide ...
Page 13
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor ...
Page 14
APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why ...
Page 15
Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates “hiccup mode,” which ...
Page 16
Standards & Qualifications Parameter STANDARDS COMPLIANCE UL 60601-1:2003 CAN.CSA 22.2 No. 601.1-M90 EN 60601-1/A2:1995 IEC 60601-1/A2:1995 IEC 61000-4-2 Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new ...
Page 17
Encased Mechanical Diagram 1.536 ±0.020 (39.01 ±0.5) 1. 030 (26.16) 0.600 (15.24) 0.450 (11.43) 0.300 (7.62) 0.150 (3.81) 2.386 ± 0.020 (60.6± 0.5) 2.00 (50.8) 0.183±.020 (4.65)±0.5 NOTES 1)M3 screws used to bolt unit’s baseplate to other surfaces (such as ...
Page 18
Flanged Mechanical Drawing 2.200 ±.020 1.536 ±.020 R .065 [ 1,65 ] TOP VIEW 1.66 [ 42.2 ] 1.01 [ 25.7 ] . .183 ±.020 .70 [ 4.65 ±0 17.8 ] .800 ±.020 .02 ...
Page 19
PART NUMBERING SYSTEM The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below Output Current Thermal Design Performance Level Package ...