The GNT400 provides 400 W of DC output power in a compact package. Standby,
control and monitoring inputs and outputs provide all the essential elements for a
variety of applications including, single board computers, running motors, pumps,
and solenoids. Approval to EN60601-1 and EN60950 improves design-in time and
reduces end system compliance costs.
Input Voltage Range
Universal input, 80 - 270 VAC (See note).
Input Frequency
45 - 65 Hz
Input Current
120 VAC, 4.2 A. 230 VAC, 2.1 A.
Inrush Current
Active circuit, 37 A max. peak.
Input Fuse
F1,F2, 6.3 A for line and neutral.
Power Factor
0.99 typical, 0.96 minimum.
Earth Leakage Current
100 µA at 120 Vac, 60 Hz Normal. 400 µA at 264 V, 50 Hz Single fault.
Output Power
400 W with fan cooling. See derating chart for other conditions.
Peak Output Power
450 W for 1 minute, 10% duty cycle.
Output Voltage
See chart.
Voltage Adjustability
+/- 5% minimum.
Minimum Load
Not required.
Total Regulation
See chart.
• Compact 4” x 7” x 1.5” U Channel (1U Compatible)
• 9.5 W/in
• 100-240 VAC Input with Active PFC
• 12 to 48 V DC Output at 400 W
• 5 Vdc 100 mA Standby Output
• 12 V DC Fan Output
• Approved to UL, CSA and EN/IEC Standards
• 300 W Convection Rating
• Less than 100 μA Leakage
• Compliance to EN55011/22 Conducted Noise B
• RoHS Compliant-Category 6
SL Power Electronics Corp.
GNT400
Front End Series 400 Watt AC/DC
Universal Input Power Supply
Specifications
3
6050 King Drive
Ventura, CA 93003
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Phone:805.486.4565
Transient Response
500 µs to 1%, 0.2 A/µs, 3.5% for 50% step load change.
Turn On Time
500 ms max.
Hold-up Time
20 ms at 400 W.
Over/Undershoot
3.5% max.
Overload Protection
Cycling type, 470 W typical.
Overvoltage Protection
See chart.
Ripple and Noise
1% pk-pk max., 20 MHz BW.
Remote Sense
Compensates for up to 500 mV.
Commercial Safety Standards
UL/EN/CSA 60950-1.
Medical Safety Standards
UL/EN/IEC60601-1
Thermal Considerations
Component
T5 cover indentation
T1 Inside coil
Switching Frequency
Output 170 kHz +/-8 kHz. PFC 140 kHz +/-8 kHz.
2 Year Warranty
Fax:805.487.8911
Email:info@slpower.com
Recommended Max. Temperature
90°C
100°C
www.slpower.com

Related parts for gnt400

gnt400 Summary of contents

Page 1

... Less than 100 μA Leakage • Compliance to EN55011/22 Conducted Noise B • RoHS Compliant-Category 6 The GNT400 provides 400 output power in a compact package. Standby, control and monitoring inputs and outputs provide all the essential elements for a variety of applications including, single board computers, running motors, pumps, and solenoids ...

Page 2

... GNT400 Front End Series 400 Watt AC/DC Universal Input Power Supply Model Volts Number GNT412ABG 12 V GNT424ABG 24 V GNT428ABG 28 V GNT436ABG 36 V GNT448ABG 48 V Note 1. When the input voltage is <90 Vac, derate output power to 300 W fan cooled or 250 W convection. 2. Using cover options allows for 400 W continuous operation up to 40°C. 3. For 400W @ 50°C, use 100 Ifm fan cooling. General Specifications (continued from p. 1) ...

Page 3

... GNT400 Front End Series 400 Watt AC/DC Universal Input Power Supply Mounting Options SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.com ...

Page 4

... GNT400 Front End Series 400 Watt AC/DC Universal Input Power Supply Mounting Options (continued from p.3) SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.com ...

Page 5

... GNT400 Front End Series 400 Watt AC/DC Universal Input Power Supply Mounting Options (continued from p.4) SL Power Electronics Corp. • 6050 King Drive • Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. Rev. 10/16/08 Ventura, CA 93003 • Phone:805.486.4565 • ...

Related keywords