GLC110
110 Watt Global Performance Switchers
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 90 Vac, 60 Hz with full rated
output load not to exceed 2.9 A.
Hold-up Time
20 ms minimum from loss of ac input at full load, nominal
line (120 Vac).
Output Power
Normal continuous output power is 75 W for unrestricted
natural convection, or 110 W with 26 cfm air flow.
Output Regulation
Load regulation on dual output models is measured by
±40% load change from 60% rated load and input
voltage change from minimum to maximum ratings.
Output #1 requires 1A minimum load for proper regula-
tion of other outputs. Initial set tolerance is measured with
all outputs at 60% of full rated load. Load regulation for
single-output models measured by changing load from
5% to 50% load or 50% to full load in either direction.
Voltage Adjustment
Output #1 adjustment is ±5%. Note: output #1 must not be
more than 1% below nominal to achieve full output
regulation on output #2. High voltage settings may
degrade the reliability of the unit due to excessive power
dissipation in some outputs.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit. Factory
set to begin power limiting at 120 W.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
POWER FAIL
Power fail signal is TTL or CMOS compatible (output goes
low <0.5 V) 5 ms before output voltage drops more than
4% below nominal voltage upon loss of AC power. The
signal is factory set to trip on 84 to 94 Vac brown-out
depending upon incoming line impedance and distortion.
Commercial/GLM110 Medical
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
FEATURES:
• Cost-effective power source
• Single- and multiple-output units
• Low height (1.30")
• 2-year warranty
• Power fail signal standard
• Commercial Approved to UL1950, IEC950
• Medical Approved to UL2601-1, EN60601,
• Complies with EN61000-3-2 Class A
Other settings are available to the user through adjust-
ment of built in potentiometer (consult factory for assis-
tance). Output will stay low for 20 ms minimum.
Transient Response
Main Output: 500 µs typical response time for return to
within 0.5% of final value for a 50% load step change, i/
shutdown overshoot less than 3%.
Turn-On Time
Less than 1 second at 120 Vac, 25
Overvoltage Protection
Built in on main output.
Efficiency
72-85% depending on model.
Input Protection
Internal ac fuse provided on all units. Designed to blow
only if a catastrophic failure occurs in the unit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC110 EN55022 Class B; FCC Class B
Conducted Emissions GLM110 EN55011 Class B; FCC Class B
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No.
234 Level 3, IEC950 and EN60950. Consult factory for
approval status.
Medical Safety
All GLM models are approved to UL2601-1, CSA-C22.2 No.
601.1, IEC601-1/60601-1. Consult factory for approval status.
t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
CSA22.2 No. 234
CSA-C22.2 No. 601.1
marked to LVD
EN61000-4-5, 1 kV diff., 2 kV com.
COMPLIANCE LEVEL
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-4, 2 kV, 5 kHz
EN61000-3-2 Class A
EN61000-4-3, 3 V/meter

Related parts for glc110

glc110 Summary of contents

Page 1

... EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC110 EN55022 Class B; FCC Class B Conducted Emissions GLM110 EN55011 Class B; FCC Class B Static Discharge EN61000-4- contact air RF Field Susceptibility EN61000-4-3, 3 V/meter ...

Page 2

... A. Rating with unrestricted convection cooling. Total power not to exceed output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. GLC110/GLM110 MECHANICAL SPECIFICATIONS E ...