gpc50 SL Power Electronics, gpc50 Datasheet

no-image

gpc50

Manufacturer Part Number
gpc50
Description
Gpc50 Commercial 50 Watt Global Performance Switchers
Manufacturer
SL Power Electronics
Datasheet
32
GPC50 Commercial
50 Watt Global Performance Switchers
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
output load: 1.5 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
50 W continuous, 60 W peak. Peak ratings are for 60 s
maximum duration, 10% duty cycle. During peak load
condition, output regulation may exceed total regulation
limits.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit on
outputs 1 & 2; foldback type on output 3. Recovery after
fault is automatic. See output ratings chart for additional
notes or conditions.
Overvoltage Protection
Crowbar provided on V1.
Efficiency
65% at full rated load, nominal input voltage, depending
on model and load distribution.
Turn-on Time
Less than 1 second at 120 Vac, 25°C (inversely propor-
tional to input voltage and thermistor temperature).
Input Protection
Internal ac fuse provided. Designed to blow only if a
catastrophic failure occurs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac
under cold start conditions will not exceed 34 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
Environmental
Designed for 0 to 50°C operation at full rated output
power; derate output current and total output power by
2.5% per °C above 50°C. See Environmental and
Packaging Specifications on next page.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
Main output—500 µs typical response time for return to
within 0.5% of final value for a 50% load step change. i/
shutdown overshoot less than 3%.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
Commercial EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Leakage Current
0.7 mA 254 Vac @ 60 Hz input.
Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
and EN60950; UL file #E135803 commercial; CSA
#LR46516 all models. The output(s) are intended for
safety earthed Signal Output and Intermediate Circuits
only. All DC outputs are SELV under normal and single
fault conditions.
FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Approved to UL1950, IEC950 and CSA22.2-234 L3
• Exceeds FCC and CISPR22 Class B conducted
• Single and multiple outputs
t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
emissions requirements
marked to LVD
EN61000-4-5, 1 kV diff., 2 kV com.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-3, 3 V/meter

Related parts for gpc50

gpc50 Summary of contents

Page 1

... GPC50 Commercial 50 Watt Global Performance Switchers SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at 120 Vac with full rated output load: 1.5 A Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Output Power 50 W continuous peak ...