104KT1608T ETC1 [List of Unclassifed Manufacturers], 104KT1608T Datasheet - Page 38

no-image

104KT1608T

Manufacturer Part Number
104KT1608T
Description
THERMOPILE TYPE INFRARED SENSOR
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
38
ZENAMIC
Reliability
Electrical
Characteristics
Temperature Coefficient of
Varistor Voltage
Standard Test Condition
Varistor Voltage
Maximum Allowable Voltage
Clamping Voltage
Rated Power
Maximum Energy
Maximum
Peak Current
(Withstanding
Surge Current)
Capacitance
Withstanding Voltage
(Body lnsulation)
lmpulse Life
2 times
1 times
Unless other wise specified, electrical measurements (initial/aftertests) shall
be conducted at temperature of 5 to 35 C,relative humidity of 45 to 85%
and atmospheric pressure of 860 to 1060 hPa.
The voltage between two terminals with the specified measuring current C
DC applied is called Vc or Vc
possible to avoid heat affection.
The maximum sinusoidal RMS voltage or maximum DC voltage that can be
applied continuously in the specified operating temperature range.
The power that can be applied in the specified ambient temperature.
The maximum energy within the varistor voltage change of
single impulse current of 2 ms or 10/ 1000 s is applied.
The maximum current within the varistor voltage change of
standard impulse current of 8 / 20 s is applied two times with an interval of
5 minutes.
The maximum current within the varistor voltage change of
single standard impulse current of 8 / 20 s is applied .
Vc
Capacitance shall be measured at 1kHz
below 100pF),0 V bias and 20 2 C
The specified voltage shall be applied between both terminals of the
specimen connected together and metal foil closely wrapped round its body
for 1 minute.
The change of Vc
below is applied 10000 or 100000 times continuously at intervals of 10
seconds at room temperature.
The maximum voltage
between two terminals
with the specified
standard impulse current
(8/20 s) illustrated
below applied.
Part NO.
mA
at 85 C Vc
Classification(Nominal varistor voltage)
Z 5 D1 8 0 to Z 5D680
Z 7 D1 8 0 to Z 7D680
Z21D180 to Z21D680
Z 5 D8 2 0 to Z 5D471
Z 7 D8 20 to Z 7D511
Z10D180 to Z10D680
Z15D180 to Z15D680
Z10D820 to Z10D102
Z15D820 to Z15D102
Z21D820 to Z21D102
Vc
mA
at 25 C
V
V
0.1mA .
0.1mA .
mA
mA
at 25 C
shall be measured after the impulse current listed
V
V
1mA
1mA
Test Methods/Descriptions
330V
330V
mA
. The measurement shall be made as fast as
100
60
90
50
10
1
0
100(%/ C)
lmpulse Life( )
130( 8 / 20 s)
100( 8 / 20 s)
150( 8 / 20 s)
200( 8 / 20 s)
250( 8 / 20 s)
8m s
25( 8 / 20 s)
50( 8 / 20 s)
90( 8 / 20 s)
40( 8 / 20 s)
8( 8 / 20 s)
10%,1Vrms max.(1MHz 10%
10
20m s
4
Times
impulse current
Test voltage(AC)
1000 Vrms
1500 Vrms
lmpulse Life( )
110( 8 / 20 s)
120( 8 / 20 s)
10% when a
15( 8 / 20 s)
35( 8 / 20 s)
50( 8 / 20 s)
65( 8 / 20 s)
25( 8 / 20 s)
60( 8 / 20 s)
85( 8 / 20 s)
10% when a
10% with a
Time
5( 8 / 20 s)
10
5
Times
(A)
mA
To meet the
specified value.
0 to 0.05% / C max.
To meet the specified
value
No breakdown
Vc
mA
Criterion
/ Vc
mA
10%

Related parts for 104KT1608T