185376-01 NI [National Instruments Corporation], 185376-01 Datasheet

no-image

185376-01

Manufacturer Part Number
185376-01
Description
Configurable Signal Conditioning Enclosure
Manufacturer
NI [National Instruments Corporation]
Datasheet
Overview
The National Instruments CA-1000 is a configurable enclosure
designed for maximum user-defined I/O connectivity and flexibility.
It is a portable enclosure for laptop, desktop, and rack-mount
applications. You can install many NI accessories in the NI CA-1000,
such as the SC-204x signal conditioning products, and the SCB-68,
CB-68LPR,
is a compact, portable, flexible, and comprehensive signal
conditioning/interconnection system. The CA-1000 also facilitates
quick connection and disconnection with standard I/O connectors
for easy system integration and reconfiguration. By adding interface
panelettes, such as toggle switches, potentiometers, and LEDs, you
can control and verify system operation locally.
CA-1000 Enclosure
The metal enclosure provides a low-profile, portable housing for
signal conditioning and connector accessories. You can place the
enclosure under a laptop PC, on a benchtop, or in a 19 in. rack.
You can also stack two or more enclosures with the stacking kit.
The CA-1000 enclosure includes five cable entry options, so you can
place the 68-pin or 50-pin connector for the cable to your DAQ
device on either the side or the rear of the CA-1000 enclosure. Please
note that the CA-1000 is shipped without any panelettes, signal
conditioning accessories, connector blocks, or cables. These
components must be ordered separately.
NI CA-1000
• Versatile connector/enclosure system
• Houses signal conditioning and
• Wide variety of I/O connectivity
• Holds maximum of
• Low-profile enclosure
• Rack-mount and stacking
I/O Connectivity Options
• BNC
• Thermocouple
• Banana jack
• LEMO connector (B-Series)
• MIL-spec
• SMB
• 9-pin D-Sub
• Strain relief
connector block accessories
and panelette options
18 connectivity/interface panelettes
kits available
and
Configurable Signal Conditioning Enclosure
CB-50LP
terminal
Interface Panelettes
• Momentary pushbutton
• Potentiometer
• Toggle switch
• Rocker switch
• LED
blocks.
The
result
Internal Accessories
The CA-1000 houses a variety of signal conditioning and data
acquisition
CB-68LPR, and CB-50LP. You mount these accessories using
hardware in the bottom panel of the CA-1000 enclosure. To install
the SCB-68 in the CA-1000, you must first remove it from its own
metal enclosure.
I/O Panelettes
The CA-1000 includes a user-configurable signal connection
scheme.
interchangeable panelettes. The panelettes, which come with
standard signal connectors – for example, BNC, SMB, banana jack,
thermocouple plugs, and LEMO, MIL-Spec, and 9-pin D-Sub
connectors – mount in the front of the CA-1000 enclosure.
The CA-1000 front panel offers nine panelette slots. The rear panel
can also be removed offering nine more panelette slots. However,
this option is not available if you are using the SCB-68 inside the
CA-1000. You can mix and match different types of panelettes. Each
panelette (except for the strain-relief panel) includes lead wires that
you connect to the screw terminals of the accessory mounted inside
the CA-1000. You can therefore connect the panelettes to any I/O
signal available on the accessory.
This
accessories,
connectivity
including
flexibility
the
is
SC-204x,
achieved
SCB-68,
with

Related parts for 185376-01

185376-01 Summary of contents

Page 1

Configurable Signal Conditioning Enclosure NI CA-1000 • Versatile connector/enclosure system • Houses signal conditioning and connector block accessories • Wide variety of I/O connectivity and panelette options • Holds maximum of 18 connectivity/interface panelettes • Low-profile enclosure • Rack-mount and ...

Page 2

Configurable Signal Conditioning Enclosure Interface Panelettes National Instruments also offers interface panelettes, which expand the functionality of the CA-1000. Interface panelettes include traditional interface controls and displays, such as rocker switches, toggle switches, momentary switches, potentiometers, and LEDs. Using interface ...

Page 3

... Blank ..............................................................................184483-01 Momentary push-button switches (2 included) ........185380-01 Rocker switch (on/off/on) ............................................185379-01 Toggle switches (on/off/on, 2 included) ......................185378-01 Potentiometer (10 kΩ, single-turn) ............................185377-01 LEDs (4 included-1 green, 1 red, 1 orange, 1 yellow) ....................................................185376-01 External Cables SH68-68-EP, 1 m......................................................................184749-01 SH68-68-D1 .....................................................................183432-01 SH68-68R1-EP .................................................................187051-01 SH50-50 ...........................................................................777720-01 R6868 ...

Page 4

NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to ...

Related keywords