VCA3 Data Sheet
The VCA3 qualification tests have included:
Handling Precautions
Although ESD protection circuitry has been designed into the the VCA3, proper precautions should be taken
when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for
ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit
parameters used to define the model. Although no industry wide standard has been adopted for the CDM, a
standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and therefore can be
used for comparison purposes.
Suggested IR profile
Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow conditions,
Table 6 shows max temperatures and lower temperatures. A peak temperature of 240°C minimum should be
used to reflow the lead solder.
Vectron International 267 Lowell Rd, Hudson NH 03051
Table 4. Environnemental Compliance
Table 5. ESD Ratings
Reliability
Table 6. Reflow Profile (IPC/JEDEC J-STD-020)
Preheat Time
Ramp Up
Time Above 217
Time To Peak Temperature
Time At 260
Time At 240 °C (max)
Ramp Down
Charged Device Model
Parameter
Human Body Model
o
C (max)
o
C
Model
Mechanical Shock
Mechanical Vibration
Temperature Cycle
Gross and Fine Leak
Resistance to Solvents
Parameter
Symbol
t
R
R
AMB-P
t
t
t
t
p2
UP
DN
S
L
P
Tel: 1-88-VECTRON-1
Minimum
1000
1500
MIL-STD-883 Method 2022
MIL-STD-883 Method 2007
MIL-STD-883 Method 1010
MIL-STD-883 Method 1014
MIL-STD-883 Method 2015
e-mail vectron@vectron.com
150 sec Min, 200 sec Max
60 sec Min, 150 sec Max
Conditions
3
6
480 sec Max
10 sec Max
60 sec Max
o
o
MIL-STD-883 Method 3115
Value
C/sec Max
C/sec Max
JESD 22-C101
Conditions