SRSB-50T03C BEL [Bel Fuse Inc.], SRSB-50T03C Datasheet

no-image

SRSB-50T03C

Manufacturer Part Number
SRSB-50T03C
Description
ISOLATED DC/DC CONVERTERS
Manufacturer
BEL [Bel Fuse Inc.]
Datasheet
Features
Applications
Description
The xRSB-50T03C is an isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit will
provide up to 50 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and
low cost. Features include remote on/off, over current protection and under voltage lockout. The converter is
provided in an industry standard sixteenth brick package.
Part Selection
Notes: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Part Number Explanation
x R SB – 50 T 03 C
1 2
1---“x” can be “0” or “S”, “0” mean through hole mount and “S” mean surface mount
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name, 1/16 brick
4---Series code
5---Input range (36-75V)
6---Output voltage (3.3V)
7---Suffix
Jul. 09, 2010
Output Voltage
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
Isolated
High Efficiency
Fixed Frequency (600 kHz)
High Power Density
Input Under Voltage Lockout
Low Cost
Positive/Negative Remote Sense
Class 1, Category 2, Isolated DC/DC Converter (refer to IPC-9592)
UL60950-1 Recognized (UL/cUL) (Pending)
Networking
Computers and peripherals
Telecommunications
xRSB-50T03C
3.3 Vdc
3
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 •
4
5 6
36 Vdc - 75 Vdc
Input Voltage
7
RoHS Compliant
3.3 Vdc/15 A Output
Max. Output
Current
15 A
Output Over Voltage Shutdown
Output Voltage Trim
Over Temperature Protection
SCP/OCP
Basic Insulation
Remote On/Off
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Max. Output
Rev.B
Power
50 W
Efficiency
Typical
89%
www.belfuse.com
Model Number
xRSB-50T03C
Active Low
1

Related parts for SRSB-50T03C

SRSB-50T03C Summary of contents

Page 1

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 xRSB-50T03C RoHS Compliant Features • Isolated • High Efficiency • Fixed Frequency (600 kHz) • High Power Density • Input Under Voltage Lockout • Low Cost • Positive/Negative ...

Page 2

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Absolute Maximum Ratings Parameter Continuous non-operating Input Voltage Input Transient Voltage Remote On/Off I/O Isolation Voltage Ambient Temperature Storage Temperature Note: Ratings used beyond the maximum ratings may ...

Page 3

... Vin=48Vdc, Ta=25°C, 200 uS with a 1µF ceramic capacitor and 250 mV the minimum external cap at output 200 uS Unit - % V =48 V, full load kHz ℃ Calculated Per Bell Core SR-332 - (Vin=48V, Vo=3.3V, Io=80%load °C, FIT=10 - 0RSB-50T03C - SRSB-50T03C V - Ohm - pF www.belfuse.com Notes Notes a 9 /MTBF) 3 ...

Page 4

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Efficiency Data 90.00% 85.00% 80.00% 75.00% 70.00% 65.00% 60.00% 55.00% 50.00% Thermal Derating Curve Maximum junction temperature of semiconductors derated to 120 degree C. Bel Fuse Inc. 206 ...

Page 5

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Thermal Derating Curve (continued) Temperature reference points on top side Ripple and Noise Waveform Note: Ripple and noise at full load, and with a 1uF ceramic cap and ...

Page 6

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Transient Response Waveforms 50%-75% Load Transients at Vin=48 V Note: Transient response at di/dt=0.1A/us, with 1uF ceramic cap and 3000uF cap at output, and Ta=25 deg C. Remote ...

Page 7

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Output Trim Equations Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected between the Trim pin and GND pin. The Trim ...

Page 8

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Remote Sense This module has remote sense compensation feature. It can minimize the effects of resistance between module’s output and load in system layout and facilitates accurate voltage ...

Page 9

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Startup & Shutdown Rise time Startup time Startup from Vin Ch1: Vo, Ch2: Vin Test Condition: 48Vin, 3.3V/15A Shutdown Bel Fuse Inc. 206 Van Vorst Street, Jersey City, ...

Page 10

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Over Current Protection To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry and can endure current limiting for a few ...

Page 11

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Over Voltage Protection The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the voltage on the output terminals exceeds the over ...

Page 12

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Over Temperature Protection The OTP is achieved by thermistor U1 and the threshold is set at 120C in non-latch mode; the hottest component Q5 reaches 130C with 100LFM ...

Page 13

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Mechanical Outline 0RSB-50T03C Note: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered using a peak solder temperature of no more than 260 ...

Page 14

... ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, Jul. 09, 2010 Mechanical Outline (continued) SRSB-50T03C Note: This module is recommended and compatible with Pb-Free Reflow Soldering and must be soldered using a reflow profile with a peak temperature of no more than 260ºC for less than 5 seconds. Note: 1) All Pins: Material - Copper Alloy; ...

Page 15

ISOLATED DC/DC CONVERTERS 36 Vdc - 75 Vdc Input, 3.3 Vdc/15 A Output Jul. 09, 2010 Revision History Date Version 2010-3-23 A First release 2010-7-9 B Update the Outline drawing of 0RSB-50T03C RoHS Compliance Complies with the European Directive 2002/95/EC, ...

Related keywords