70M-IDCI5NP GRAYHILL [Grayhill, Inc], 70M-IDCI5NP Datasheet

no-image

70M-IDCI5NP

Manufacturer Part Number
70M-IDCI5NP
Description
AC/DC Input Modules
Manufacturer
GRAYHILL [Grayhill, Inc]
Datasheet
FEATURES
• Transient Protection: Meets the
• Non-Polarized Types Provide
• UL, CSA, CE , TÜV Certified (TÜV
• Optical Isolation
• OpenLine
CIRCUITRY
SPECIFICATIONS: By Package Style
1
2
3
I/O
16
requirements of IEEE 472, “Surge
Withstanding Capability Test”*
Inputs For AC or DC
not available on OpenLine)
Built-in Status LED
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
Package Style
Specifications
Output Current Range
Min. Output Breakdown Voltage
Isolation Voltage
Vibration
Mechanical Shock
Storage Temp. Range
Operating Temp. Range
Warranty
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
2
®
and G5 Modules have
+
VDC
+VCC
OUTPUT
GROUND
Status LED in G5 modules only.
Standard, Mini, G5
1
3
1
2
3
4
5
AC/DC Input Modules
REGULATING
Rx
CURRENT
HYST. CIRC.
VOLTAGE
INPUT
Units
Vrms
Vdc
mA
°C
°C
TERMINAL
BLOCK #
SUPPLY
I/O MODULE
PIN #
DC
MIL-STD-202
MIL-STD-202
DEVICE
DEVICE
INPUT
INPUT
-40 to +125
-40 to +100
*
Std (70-)
Lifetime
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
70L-IDC
4000
1-50
50
1
2
3
4
BASE
RACK
OR
1
2
3
4
2
+/-
+/-
+/-
+/-
, 10-150 Hz.
70G-IDC
MIL-STD-202
MIL-STD-202
TYPICAL WIRING FOR MODULE 0
* Separate supplies may also be used.
Mini (70M-)
-40 to +125
-40 to +100
Lifetime
4000
1-50
50
FILTER
FILTER
OpenLine
ISOLATION
ISOLATION
OPTICAL
OPTICAL
MODULE
70-IDC
®
HYSTERESIS
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
G5 (70G-)
Lifetime
HYSTERESIS
4000
1-50
A
50
B
0Ω
70M-IDC
6
7
8
9
5
IEC68-2-27
-40 to +100
Vcc
CH. A STATUS
GND
CH. B STATUS
MODULE ID
OL (70L-)
IEC68-2-6
-40 to +85
Lifetime
2500
1-50
50

Related parts for 70M-IDCI5NP

70M-IDCI5NP Summary of contents

Page 1

... INPUT 3 3 FILTER DEVICE DC * SUPPLY +/- 4 4 BASE TERMINAL OR BLOCK # RACK * Separate supplies may also be used. Std (70-) Mini (70M-) Units mA 1-50 1-50 Vdc 50 50 Vrms 4000 4000 MIL-STD-202 MIL-STD-202 MIL-STD-202 MIL-STD-202 °C -40 to +125 -40 to +125 °C -40 to +100 -40 to +100 Lifetime ...

Page 2

... Vac/Vdc 35-60 15-32/10- mSec 10 5 mSec 10 5 Ω 10.6K 1.9K Vac/Vdc 35 15/10 Vac/Vdc 9 3 Vdc 5 5 Vdc 4.5-28 4.5-28 mA 6/CH 6/CH Ω 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com 70M-IDCI5NP 70-IDC15NP 70-IDC24NP 32 32 15-32/10-32 15-32/10- 1.8K 1.8K 15/10 15/ 8-18 15- 70G-IDC15NP 70G-IDC24NP 32 32 15-32/10-32 15-32/10- ...

Related keywords