SL220-4605 ARTESYN [Artesyn Technologies], SL220-4605 Datasheet

no-image

SL220-4605

Manufacturer Part Number
SL220-4605
Description
Single output 115/230 VAC input Floating output
Manufacturer
ARTESYN [Artesyn Technologies]
Datasheet
SPECIFICATION
OUTPUT SPECIFICATIONS
Output voltage
adjustability
Line regulation
Load regulation
Overshoot/undershoot
Transient response
Temperature coefficient SL120, all outputs
Overvoltage protection
Output power limit
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Maximum input
surge current
Safety ground
leakage current
PAGE 1
[ 2 YEAR WARRANTY ]
SL120 only
5V Models
24V Models
LL to HL, FL
60% FL, ±40%
SL120
SL220
At turn-on
SL120: +5V (12A to 20A)
SL220: +5V (10A to 20A)
SL220, all outputs
5V output
SL120
SL220
User Selectable
SL120: 230VAC, cold start
SL220: 230VAC, cold start
230VAC Input, 50Hz
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
170 to 264VAC
47Hz to 440Hz
85 to 132VAC
1ms recovery
1ms recovery
4.5V to 5.5V
6.25 ±0.75V
SL120 and SL220 SERIES
Single output
SL120: For new design-ins see the NFS110 Series instead
SL220: For new design-ins see the NFS200 and LX200 Series instead
• 115/230 VAC input
• UL, CSA and (VDE approved - SL120 only)
• Short circuit protection
• Floating output
• 20ms hold-up time min.
This series of 100 Watt to 220 Watt single output switchers use an advanced
circuit topology providing superior performance at low cost. Smaller and lighter
than equivalent linear supplies, they are available in 5V and 24V output versions.
The floating outputs can be referenced as either positive or negative. The SL120
model is UL, CSA and VDE approved. Also, selected models incorporate remote
sense. SL120/220 Series power supplies are suitable for a wide variety of
applications, including front end power systems, general industrial and telecom
equipment.
18V to 26V
±0.03%/°C
±0.05%/°C
130W min.
260W min.
±300mV,
±100mV,
±0.2%
±2.0%
±1.0%
0.7mA
None
22A
74A
Yes
GENERAL SPECIFICATIONS
Hold-up Time
Efficiency
Isolation voltage
Approvals and
standards
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Relative humidity
Altitude
Low line, full load
SL120, 110VAC
SL120, 230VAC
SL220, 110VAC
SL220, 230VAC
SL220 Input/Output
SL220 Input/Chassis
SL120 Input/Output
SL120 Input/Chassis
Safety: SL120 series
SL120
SL220
SL120
SL220
Operating, See Note 8
Non-operating
Non-condensing
Operating
Non-operating
CSA bulletin No. 1402C
25,000 hours min.
50,000 hours min.
EN60950, UL478
10,000 feet max.
30,000 feet max.
–40°C to +85°C
5% to 80% RH
1.2kg (42.4oz)
2.3kg (81.2oz)
0°C to +70°C
65%, max.
VDE0805,
1500VAC
1500VAC
3750VAC
1500VAC
36ms
36ms
20ms
20ms

Related parts for SL220-4605

SL220-4605 Summary of contents

Page 1

... SL120 and SL220 SERIES Single output SL120: For new design-ins see the NFS110 Series instead SL220: For new design-ins see the NFS200 and LX200 Series instead • 115/230 VAC input • UL, CSA and (VDE approved - SL120 only) • Short circuit protection • ...

Page 2

... Measured from low line to high line at full load. 5 Measured at 60% full load, ±40%. 6 The SL220-4605 offers an auxiliary 24V output, rated pin 7. The SL220-4624 offers an auxiliary 48V output, rated pin 7. 7 Output sense will compensate for up to 3VDC load line drop. The output current limit increases with output voltage ...