TISP61089AS POINN [Power Innovations Ltd], TISP61089AS Datasheet

no-image

TISP61089AS

Manufacturer Part Number
TISP61089AS
Description
DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS?
Manufacturer
POINN [Power Innovations Ltd]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TISP61089ASDR
Manufacturer:
BOURNS
Quantity:
17 964
Copyright © 1999, Power Innovations Limited, UK
description
P R O D U C T
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.
V
60 Hz POWER
The TISP61089AS is a dual forward-conducting buffered p-gate overvoltage protector. It is designed to
protect ringing SLICs (Subscriber Line Interface Circuits) against overvoltages on the telephone line caused
by lightning, a.c. power contact and induction. The TISP61089AS limits voltages that exceed the SLIC supply
rail voltage. The TISP61089AS parameters are specified to allow equipment compliance with Bellcore GR-
1089-CORE, Issue 1.
WAVE SHAPE
ELEMENT
GG
FAULT TIME
VOLTAGE
10/700 µs
Crowbar
Dual Voltage-Programmable Protectors
— High Voltage Rating ........................-120 V
— Wide Programming Range..... 0 to -100 V
— Low Gate Triggering Current .......< 5 mA
— High Holding Current ................> 150 mA
Increased Gound Pin Clearance Version of
— Ground Lead Creepage ................ > 3 mm
— Small Outline Surface Mount Package
Rated for LSSGR ‘1089 Conditions
2/10 Protection Voltage Specified
Rated for ITU-T K20 & K21 impulses
10/1000 µs
Diode
2/10 µs
100 ms
= -48 V
300 s
900 s
1 s
5 s
WAVE SHAPE
TISP61089AD
FIRST-LEVEL
CURRENT
RINGING SLIC OVERVOLTAGE PROTECTION FOR LSSGR ‘1089
4.5.8 Second-Level 1
4.5.7 First-Level 3
4.5.13 Second-Level 2
4.5.13 Second-Level 2
4.5.13 Second-Level 2
4.5.13 Second-Level 1
4.5.13 Second-Level 1
V @ 56 A
‘1089 TEST CLAUSE
‘1089 TEST CLAUSE
5/320
-57
I N F O R M A T I O N
6
AND TEST #
AND TEST #
I
SECOND-LEVEL
TSP
40
A
V @ 100 A
-60
8
I
0.95
0.92
I
120
TSM
4.8
2.7
TSP
30
11
A
A
Taped and reeled
CARRIER
DUAL FORWARD-CONDUCTING P-GATE THYRISTORS
Tube
AVAILABLE OPTIONS
PROGRAMMABLE OVERVOLTAGE PROTECTORS
device symbol
TISP61089ASDR
TISP61089ASD
ORDER #
Terminals K1, K2 and A correspond to the alternative
line designators of T, R and G or A, B and C. The
negative protection voltage is controlled by the
voltage, V
(Tip)
(Gate)
(Ring)
Terminal typical application names shown in
A
A
G
NC
K2
K1
NC - No internal connection
GG,
applied to the G terminal.
D PACKAGE
(TOP VIEW)
parenthesis
1
2
3
4
K1
K2
8
7
6
5
NC
A
A
NC
(Ground)
(Ground)
TISP61089AS
G1,G2
MD6XBA
OCTOBER 1999
SD6XAP
1

Related parts for TISP61089AS

TISP61089AS Summary of contents

Page 1

... The TISP61089AS is a dual forward-conducting buffered p-gate overvoltage protector designed to protect ringing SLICs (Subscriber Line Interface Circuits) against overvoltages on the telephone line caused by lightning, a.c. power contact and induction. The TISP61089AS limits voltages that exceed the SLIC supply rail voltage. The TISP61089AS parameters are specified to allow equipment compliance with Bellcore GR- 1089-CORE, Issue 1 ...

Page 2

... SLIC supply during overvoltages caused by power cross and induction. The TISP61089AS is the TISP61089AD with a different pinout. The feed-through Ring (leads 4 — 5) and Tip (leads 1 — 8) connections have been replaced by single Ring (lead 4) and Tip (lead 1) connections. This increases package creepage distance of the biased to ground connections from about 0 ...

Page 3

... C Gate decoupling capacitor G TISP61089AS series resistor for first-level and second-level surge survival R S TISP61089AS series resistor for first-level surge survival electrical characteristics PARAMETER I Off-state current 2/10 µs, I 2/10 µ Breakover voltage (BO) 1.2/50 µs, I 1.2/50 µ Forward voltage ...

Page 4

... TISP61089AS DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS OCTOBER 1999 PARAMETER MEASUREMENT INFORMATION V GK(BO (BO (BO) Quadrant III Switching Characteristic Figure 1. VOLTAGE-CURRENT CHARACTERISTIC FSP TSP FSM ...

Page 5

... RING AND TIP TERMINALS: I values applied simultaneously TSM GROUND TERMINAL: Current twice I value TSM EIA /JESD51 Environment and PCB ° - - -100 100 t — Current Duration — s APPLICATIONS INFORMATION TISP61089AS OCTOBER 1999 TI6LAE 1000 5 ...

Page 6

... Figures 4. and 5. show how the TISP61089AS limits negative and positive overvoltages. Positive overvoltages (Figure 5) are clipped by the antiparallel diodes in the TISP61089AS and the resulting current is diverted to ground. Negative overvoltages (Figure 4.) are initially clipped close to the SLIC negative supply rail value (V ) ...

Page 7

... DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS SLIC V BAT Figure 5. POSITIVE OVERVOLTAGE CONDITION V K 0.0 0.5 1.0 Time - µ 0.0 0.5 1.0 Time - µs TISP61089AS OCTOBER 1999 SLIC SLIC PROTECTOR I Th5 F TISP 61089AS V BAT C1 220 nF AI6XCAA V BAT 1 1.5 ...

Page 8

... FOR Th1 & Th2 ONLY USE A TISP3xxxF3/H3 Relay contacts 3a and 3b connect the line conductors to the SLIC via the TISP61089AS protector. The protector gate reference voltage comes from the SLIC negative supply (V sources the high gate current pulses caused by fast rising impulses. ...

Page 9

... As shown in table 1, the peak currents for these surges are 2x20 A and 2x56 A respectively. The protector must survive the 2x20 A 10/1000 surge and the TISP61089AS will do this as its rating is 2x30 A. When both conductors are surged simultaneously the return (anode) current will again the TISP61089AS will survive this as its rating for this condition will ...

Page 10

... The 2/10 generator has fictive output resistances of 15 compensates for this by adding an extra resistances of 12 generator. In practice, this extra resistance causes the prospective short-circuit current wave shape to be similar to the 1.2/50 open-circuit voltage wave shape. The TISP61089AS will survive the 2x27 A 1.2/50 as its rating is 2x100 ...

Page 11

... The most significant tests are a long duration (900 s) medium current test and a higher current tests of 60 one second power applications. As shown in table 4, the peak currents for these tests are 2x0.37 A and 2x1.3 A respectively gate voltage of -80 V, the TISP61089AS will survive both these conditions as its ratings are 2x0.92 A and 2x4.8 A for these time periods A ...

Page 12

... Using a 25 series resistor will result in table 5. I and 2x2.9. The TISP61089AS will probably fail for a peak current level of 2x24 A and the series current limiting element must operate in under 0. prevent exceeding the TISP61089AS package limit. For 2x7.7 A, the series current limiting element must operate within 0.3 s for TISP61089AS survival. ...

Page 13

... MDQ 1-6/10A fusing characteristic. Fusible overcurrent protectors cannot operate at first level current levels. Figure 9 shows two other curves. One is the TISP61089AS rated current at gate voltage of -100 V and the other for a gate voltage of -60 V. The overcurrent protector should not allow current-time durations greater than this otherwise the TISP61089AS may fail ...

Page 14

... TISP61089AS DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS OCTOBER 1999 OVERCURRENT PROTECTOR OPERATION LIMITS 30 Second Level Tests - Second Level Tests - 0.7 0.5 0.3 0.2 0.1 0.01 Figure 9. OVERCURRENT PROTECTOR REQUIREMENTS TIME 0.1 1 Time - s AI6XALB ...

Page 15

... Places Pin Spacing 0,229 (0.0090) 1,27 (0.050) 0,190 (0.0075) (see Note A) 6 Places TISP61089AS OCTOBER 1999 Designation per JEDEC Std 30: PDSO-G8 5,21 (0.205) 4,60 (0.181) 7° NOM 4° ± 4° 4 Places 1,12 (0.044) 0,51 (0.020) MDXXAA 15 ...

Page 16

... TISP61089AS DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS OCTOBER 1999 Power Innovations Limited (PI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to verify, before placing orders, that the information being relied on is current ...

Related keywords