SMFLHP2805D INTERPOINT [Interpoint Corporation Company], SMFLHP2805D Datasheet

no-image

SMFLHP2805D

Manufacturer Part Number
SMFLHP2805D
Description
Parallel operation with current share, up to 3 units (228 watts)
Manufacturer
INTERPOINT [Interpoint Corporation Company]
Datasheet
description
The SMFLHP Series™ 28 volt DC/DC converters are rated up
to 100 watts output power over a –55°C to +125°C temperature
range with a 28 VDC nominal input. On dual output models, up to
70% of the rated output power can be drawn from either the posi-
tive or negative outputs. Current sharing allows the units to be
paralleled for total power of up to 228 watts. The welded, hermet-
ically sealed package is only 3.005 x 1.505 x 0.400 inches, giving
the series an overall power density of up to 67 watts per cubic
inch.
S
SMFLHP converters offer screening options to Space Prototype
(O), Class H, or Class K. Radiation tolerant to Radiation
Hardness Assurance (RHA) levels of “-” (O), “P” or “R”, per MIL-
STD-38534. Interpoint model numbers use an “O” in the RHA
designator position to indicate the “-” (dash) Radiation Hardness
Assurance level of MIL-PRF-38534, which is defined as “no
RHA”. See “Class H and K, QML Screening” tables for more
information.
D
The SMFLHP Series converters are switching regulators that use
a quasi-square wave, single ended forward converter design with
a constant switching frequency of 600 kHz.
Isolation between input and output circuits is provided with a
transformer in the forward path and wide bandwidth magnetic
coupling in the feedback control loop. The SMFLHP Series
uses a unique dual loop feedback technique that controls output
current with an inner feedback loop and output voltage with a
cascaded voltage mode feedback loop.
The additional secondary current mode feedback loop improves
transient response in a manner similar to primary current mode
control and allows for ease of paralleling.
Crane Aerospace & Electronics
Electronics group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • electronics@craneae.com
www.craneae.com
Features
creening
eSign
Parallel operation with current share,
up to 3 units (228 watts)
-55° to +125°C operation
19 to 40 VDC input
50 V for 120 ms transient protection
Fully isolated, magnetic feedback
Fixed high frequency switching
Remote sense or output trim on single output models
Inhibit function
Synchronization input and output
Indefinite short circuit protection
High power density with up to 87% efficiency
F
eatureS
smFlHp single and dual dc/dc converters
28 Volt input – 100 Watt
OSR case number 09S-0995, dated March 13, 2009.
Cleared by u.S. DoD OSR for Public Release
Rev H - 20071221
Page 1 of 13
Tight load regulation is achieved through a wide-bandwidth
magnetic feedback circuit. The output voltage on single SMFLHP
models can be easily trimmed up by adding an external resistor.
(See Figure 2 for voltage changes with different resistor values.)
i
The SMFLHP Series converters have two inhibit terminals
(INH1 and INH2) that can be used to disable power conversion,
resulting in a very low quiescent input current. A low (<0.8 volts)
is required between INH1 (pin 4) and Input Common (pin 2) to
inhibit the converter. A low (<0.5 volts) is required between INH2
(pin 12) and Output Common (pin 8) to inhibit the converter. The
application of intermediate voltages to these pins (1.5 to 10.5
volts) should be avoided.
c
Multiple SMFLHP converters may be used in parallel to drive a
common load (see Figure 3). In this mode of operation the load
current is shared by two or three SMFLHP converters. In current
sharing mode, one SMFLHP converter is designated as a master.
The SLAVE pin (pin 11) of the master is left unconnected and
the MSTR/INH2 pin (pin 12) of the master is connected to the
SLAVE pin (pin 11) of the slave units. The units designated as
slaves have the MSTR/INH2 pin (pin 12) connected to the SNS
RTN pin (pin 9) of the master unit. Figure 3 shows the typical
setup for two or three units in parallel. Note that synchronizing
the units together (though shown in the figure) is not required for
current sharing operation. A second slave unit may be placed in
parallel with a master and slave; this requires the TRI pin (pin 3)
of the master unit to be connected to the SNS RTN pin (pin 9).
When paralleled, 76% of the total combined power ratings of the
SMFLHP converters are available at the load. Overload and short
circuit performance are not adversely affected during parallel
operation.
nhibit
urrent
SINgLE
3.3
12
15
5
VDC O
models
S
utput
haring anD
DuAL
±12
±15
±5
Crane Aerospace & Electronics Power Solutions
P
arallel
O
PeratiOn

Related parts for SMFLHP2805D

SMFLHP2805D Summary of contents

Page 1

Features Parallel operation with current share units (228 watts) • -55° to +125°C operation • VDC input • for 120 ms transient protection • Fully isolated, ...

Page 2

Operating COnditiOns and CharaCteristiCs input Voltage range • VDC continuous • for 50 msec transient output power • 100 watts depending on model lead soldering temperature (10 sec per lead) • 300°C storage temperature range (case) • –65°C to +150°C power dissipation (pd) • 20 watts case operating temperature (tc) • –55 to +125°C full power ...

Page 3

OUt pin single Output 1 Positive Input 2 Input Common 3 Triple (TRI) 4 Inhibit 1 (INH1) 5 Sync Out 6 Sync In 7 Positive Output 8 Output Common 9 Sense Return 10 ...

Page 4

OUtpUt mOdels COnneCtiOn diagrams - sense and parallel 28V Inhibit Sync In 28V Inhibit Sync In 28V Inhibit Sync In www.craneae.com 28 Volt input – 100 Watt 1 Positive Input MSTR/INH2 + 2 ...

Page 5

Number of Outputs (S = single dual) SMFLHP28 base model Choose one from each of the following rows: V value out Number of outputs Case option Screening * Interpoint model numbers use ...

Page 6

Electrical Characteristics: –55°C to +125°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified. SINgLE OuTPuT MODELS Parameter cOnDitiOnS OutPut VOltage tc = 25°c OutPut current OutPut ...

Page 7

... Effect on negative Vout from 50%/50% loads to 30%/70% or 70%/30% loads. 4. Effect on negative Vout from 50%/50% loads to 10% then 50% load on negative Vout www.craneae.com 28 Volt input – 100 Watt SMFLHP2805D cOnDitiOnS MIN TYP MAX MIN TYP MAX MIN + V 4.95 5.00 5.05 Out 4 ...

Page 8

... Typical Performance Curves: 25° VDC Vin, 100% load, free run, unless otherwise specified 19V 80 28V 75 40V Output (Watts) SMFLHP2805S & SMFLHP2805D Efficiency F 4 igure 0 100 Frequency (kHz) SMFLHP Series Audio Rejection F 7 igure Vin Vout 1ms/div ...

Page 9

... Vin Rise-time (µs) SMFLHP2815D Line Transient Response vs. Vin Rise-time F 16 igure www.craneae.com 28 Volt input – 100 Watt 8 6 SMFLHP2805D 4 2 SMFLHP2812D 0 – 2 SMFLHP2815D – 4 – 6 – Output Load (%) +Pout –Pout 30 to 70% ...

Page 10

U does not require designator in Case Option position of model number. Angled corner indicates pin one. 1.505 (38.23) max. 1.380 (35.05) 1.250 (31.75) 1.050 (26.67) 0.850 (21.59) 0.650 (16.51) 0.450 (11.43) ...

Page 11

C H lass and COmpOnent-level test perfOrmed Element Electrical Element Visual Internal Visual Temperature Cycling Constant Acceleration Interim Electrical Burn-in Post Burn-in Electrical Steady State Life Voltage Conditioning Aging Visual Inspection Final Electrical 4 ...

Page 12

C H lass and end item-level test perfOrmed Non-destruct bond pull Method 2023 Pre-cap Inspection Method 2017, 2032 Temperature Cycle (10 times) Method 1010, Cond. C, -65°C to 150°C, ambient Constant Acceleration Method 2001, ...

Page 13

C H lass and RadIatIon HaRdnEss assuRanCE lEvEls Standard, no radiation guarantee p: Radiation tolerant–Tested lots Rads (Si) total dose SEU guarantee MeV r: ...