SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION REMOTE CONTROL (CN5)
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
BOOST CHARGE VOLTAGE
FLOAT CHARGE VOLTAGE
VOLTAGE ADJUSTABLE RANGE
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
BATTERY TYPE
OUTPUT CURRENT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
POWER FACTOR (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
SHORT CIRCUIT
REVERSE POLARITY
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
360W Single Output Battery Charger
1.300W without FAN
2.360W with FAN
P:With Passive PFC
N:Without Passive PFC
(Note 5)
Protection type : Automatically derate charge current until zero
Open: Normal work
14.4V
13.6V
13 ~ 14.7V
80 ~ 200Ah
Open & Sealed Lead Acid
24.3A
90 ~ 132VAC / 180 ~ 264VAC selected by switch
47 ~ 63Hz
7A/115VAC
PB-360 -12
85%
>0.65 (with P type) at 230VAC
COLD START 60A
<3.5mA / 240VAC
90 ~ 110% rated output current
Protection type : Constant current limiting, recovers automatically after fault condition is removed
O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on
By internal fuse
16 ~ 18V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3 (only P type)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
115.8Khrs min.
253*135*48.5mm(L*W*H)
1.5Kg; 6pcs/10Kg/0.95CUFT
0.05%/
(0 ~ 45
3.5A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
Short: Stop Charging
PB
300/360
O/P-FG:0.5KVAC
27.2V
26 ~ 28.8V
40 ~ 125Ah
12.5A
28.8V
31 ~ 35V
PB-360 -24
86%
P
248 ~ 370VDC
12
12:14.4V
24:28.8V
48:57.6V
PB-360
57.6V
54.4V
52 ~ 58.6V
20 ~ 65Ah
6.25A
PB-360 -48
87%
59 ~ 64V
File Name:PB-360-SPEC 2008-11-11
series