1. Measurement condition :
Ambient temperature T
Input power level:
Terminating impedances at f c *) :
2. Characteristics
Remark:
the pass band attenuation a min is defined as the insertion loss a e . The centre frequency f c is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss a e . The nominal frequency
The given values for the relative attenuation a rel and for the group delay ripple have to be reached at the frequencies given below also if the
centre frequency f c is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and due to a production
tolerance for the centre frequency f c .
Data
Insertion loss (Reference level)
Nominal frequency
Centre frequency
Pass band ( PB ) :
Amplitude ripple in PB (p-p) :
Bandwidth :
Relative attenuation
Group delay ( mean value in PB ):
Group delay ripple (p-p) in :
Deviation from linear phase (p-p)
Triple transit attenuation compared to main signal
Crosstalk
Substrate material
Frequency inversion temperature ( T
Temperature coefficient of frequency ( Tc
Frequency deviation of f c over temperature: ** )
Operating temperature range
Storage temperature range
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) f
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
20
40
f N ± 2,05
f N ± 2,75
f N ± 5
f N - 25
f N + 7
f N ± 25
f N - 290
f N + 100
1
3
3
O
Generated:
Checked / approved:
TELEFILTER
= f
To
dB
dB
dB
dB
dB
tft@telefilter.com
Reference level for the relative attenuation a rel of the TFS 300C is the minimum of the pass band attenuation a min . The minimum of
is reference frequence f c at frequency inversion temperature (T
f N
MHz .... f N ±
MHz .... f N ±
MHz .... f N ±
MHz .... f N -
MHz .... f N +
MHz .... f N ±
MHz .... f N -
MHz .... f N +
...... f N ±
A
:
f N
f c at ambient temperature (f
a rel
100
100
700
25
2,05 MHz
2,5 MHz
5
7
7
a e
f N ... f N ± 2,2 MHz
f N ... f N ± 1,8 (2,5) MHz
o
25
0
for input:
for output:
MHz
MHz
MHz
MHz
MHz
MHz
MHz
)
f
)
°C
dBm
Dunzow W.
Dr. Bert Wall
Filter specification
CTA
176
775
)
¸« - 6,19 pF.
¸« - 3,52 pF.
f c (Hz) = Tc
o
)
43...45
49...54
49...54
55...70
-0,030
300,02
60...65 dB
17
typ. value
4,55
5,25
5,25
6,96
9,30
90
90
60
30
0,8 dB
1,1 µs
2° (2,6°)
Quartz
39 dB
f
(ppm/K) x (T - T
-
dB
-
-
-
dB
ns
°C
ppm/K²
MHz
MHz
MHz
MHz
MHz
MHz
dB
dB
dB
dB
dB
f N
o
)² x f
is fixed on 300 MHz without tolerance.
TFS 300 C
version 1.1
f
N
To
- 2,05 MHz ... f
(MHz)
max.
max.
max.
max.
max.
max.
max.
max. 100
- 20 °C ... + 70 °C
- 40 °C ... + 85 °C
tolerance / limit
min.
min.
min.
min.
min.
min.
min.
300
45
20
10
40
43
50
1
4,1
5,0
5,5
1
3
3
1,5
N
08.04.2002
+ 2,05 MHz
1/5
dB
dB
dB
dB
dB
dB
dB
dB
dB
MHz
MHz
MHz
MHz
MHz
µs
ns

Related parts for tfs300c

tfs300c Summary of contents

Page 1

... Tfs300C.doc VI TELEFILTER 1. Measurement condition : Ambient temperature Input power level: 0 Terminating impedances for input: for output: 2. Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 300C is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min is defined as the insertion loss The centre frequency the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a e ...

Page 2

... Tfs300C.doc VI TELEFILTER 3. Package, pin grid 2,54 mm TFS 300C P22 Date-code 4. 50 matching network ( please refer to the application note for further details ) : Scheme Scheme 2 1 For final test we use scheme 2. VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 tft@telefilter ...

Page 3

... Tfs300C.doc VI TELEFILTER 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...

Page 4

... Tfs300C.doc VI TELEFILTER 7. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...

Page 5

... Tfs300C.doc VI TELEFILTER History : Version Reason of Changes 1.0 Generate preliminary specification according to customer requirements 1.1 - change “ Relative attenuation ( a rel ) “ from f N ± 7 MHz ... f N ±25 MHz – 25 MHz ... f N – 7 MHz MHz ... MHz - change termination impedance from : from for input: ...