DS2000-3-001 EMERSON-NETWORKPOWER [Emerson Network Power], DS2000-3-001 Datasheet

no-image

DS2000-3-001

Manufacturer Part Number
DS2000-3-001
Description
2000 Watts 12 V Distributed Power System
Manufacturer
EMERSON-NETWORKPOWER [Emerson Network Power]
Datasheet
DS2000-3
2000 Watts 12 V
Distributed Power System
Special Features
• Active power factor correction
• EN61000-3-2 harmonic compliance
• Active AC inrush control
• 1U X 3U form factor
• 26.14 W / in
• +12 Vdc output
• +3.3 Vdc Stand-By
• No minimum load required
• Hot plug operation
• N + 1 redundant
• Internal OR’ing fets
• Active current sharing
• Built-in cooling fans
• I
• PM Bus compliant
• EERPOM for FRU data
• Red/Green bi-color LED status
• Internal fan speed control
• INTEL, SSI Std. logic timing
• INTEL, SSI Std. FRU data format
• One year warranty
• UL/cUL 60950 (UL Recognized)
• NEMKO+ CB Report EN60950
• EN60950
• CE Mark
• China CCC
Distributed Power Bulk Front-End
Total Output Power: 2000 Watts
+12 Vdc main Output
+3.3 Vdc Stand-by Output
Wide Range Input voltage: 90 - 264 Vac
Safety
(5 V standby - consult factory)
(10 - 100% load)
(40 mm x 28 mm)
2
C communication interface bus
3
Electrical Specifications
Input
Input ra n ge
Frequency
Inrush current
Efficiency
Conducted EMI
Radiated EMI
Power factor
Leakage current
Hold up time
Output
Main DC voltage
Stand-By
Adjustment range
Regulation
Overcurrent
Overvoltage
Undervoltage
Turn-on delay
+12 V Output Rise Time
90 - 264 Vac (wide range)
90 - 264 1200 W load, nominal 100 Vac
180 - 264 2000 W load, nominal 200 Vac
47 - 63 Hz, single phase AC
55 A maximum inrush current
> 89% typical at full load, high line
FCC Subpart J EN55022 Class B
FCC Subpart J EN55022 Class B
0.99 typical
1.40 mA @ 240 Vac
12 ms minimum
+12 V @ 164.2 A 180 - 264 Vac
+12 V @ 100 A
+3.3 Vsb @ 9 A (5 V @ 5 A TBA)
Factory Set, no pot adjustments
+12 Vdc; ±5%
+3.3 Vsb; ±5%
+12 Vdc; latches off if overcurrent lasts over 1 second,
otherwise it is auto recovery (See ordering info next page) +3.3
Vsb, 9 A max (same as +12 Vdc)
+12 Vdc; 13.2 - 14.4 Vdc
+3.3 Vsb; 3.76 - 4.30 Vdc
+12 Vdc; 9 - 10.8 V (latch off)
2 second max, 5 - 300 ms, Monotonic Rise
5 - 50 ms, Monotonic Rise
90 - 264 Vac
Embedded Power for
Business-Critical Continuity
Rev. 06.10.11_52
DS2000-3
1 of 4

Related parts for DS2000-3-001

DS2000-3-001 Summary of contents

Page 1

... Regulation +3.3 Vsb; ±5% +12 Vdc; latches off if overcurrent lasts over 1 second, Overcurrent otherwise it is auto recovery (See ordering info next page) +3.3 Vsb max (same as +12 Vdc) Overvoltage +12 Vdc; 13.2 - 14.4 Vdc +3.3 Vsb; 3.76 - 4.30 Vdc Undervoltage +12 Vdc 10.8 V (latch off) Turn-on delay 2 second max 300 ms, Monotonic Rise +12 V Output Rise Time ms, Monotonic Rise Embedded Power for Business-Critical Continuity Rev. 06.10.11_52 90 - 264 Vac DS2000 ...

Page 2

... Total Minimum Maximum Regulation Current ±5% 0A ±5% 0A ±5% 0A 161.5 A** ±5% 0A DS2000-3-001 Derating Curve 2500 2000 1500 1000 500 0 - Operating Temperature (°C) Low Line (90 Vac) High Line (180 Vac) Embedded Power for ...

Page 3

... Handle Laird Technologies (SEA) PTE 295.7 ± 1 (3X) 261.7 Programming Holes 8 292.1 ± 1 Latch EMI Gasket AIRFLOW DIRECTION S3700-0021-00 325.2 220.1 325.2 EMI Gasket S3700-0021-00 Embedded Power for Business-Critical Continuity 16.3 ± 0.8 99.1 ± 0.8 220.1 Rev. 06.10.11_52 DS2000 OUTPUT CONNECTOR MOLEX 45985-1462 ...

Page 4

... Main Output Emerson Network Power. Main Output The global leader in enabling Main Output business-critical continuity. Main Output Main Output AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and OPTIONAL PEGS service marks of Emerson Electric Co. ©2011 Emerson Electric Co. Rev. 06.10.11_52 DS2000 ...

Related keywords