gl846 Genesys Logic, gl846 Datasheet - Page 75

no-image

gl846

Manufacturer Part Number
gl846
Description
High Speed Usb 2.0 2-in-1 Scanner Controller With Fast Adf
Manufacturer
Genesys Logic
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GL846
Manufacturer:
GENESYS
Quantity:
20 000
©2000-2007 Genesys Logic Inc. - All rights reserved.
Offset E8h ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
7-0 G1DWN [15:8]
Offset E9h ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
7-0
Offset EAh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
7-0 G1UP[15:8]
Offset EBh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
7-0 G1UP [7:0]
Offset ECh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
7-0
Offset EDh ……..……..………………....………..…………..….………..…..…. Default value = 8’h00
G1DWN15 G1DWN14 G1DWN13 G1DWN12 G1DWN11 G1DWN10 G1DWN9
G2DWN15 G2DWN14 G2DWN13 G2DWN12 G2DWN11 G2DWN10 G2DWN9
G1DWN7
G2DWN7
G1UP15
G1UP7
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN [7:0]
G2DWN [15:8]
GL846 High Speed USB2.0 2-in-1 Scanner Controller With Fast ADF
G1DWN6
G2DWN6
G1UP14
G1UP6
R/W
R/W
R/W
R/W
R/W
R/W
Bit15~8 Registers setting for G-Channel ODD image buffer start-address. Unit is
in 1k words
Bit7~0 Registers setting for G-Channel ODD image buffer start-address. Unit is in
1k words.
Bit15~8 Registers setting for G-Channel ODD image buffer end-address. Unit is
in 1k words.
Bit7~0 Registers setting for G-Channel ODD image buffer end-address. Unit is
in 1k words.
Bit15~8 Registers setting for G-Channel EVEN image buffer start-address. Unit is
in 1k words
G1DWN5
G2DWN5
G1UP13
G1UP5
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN4
G2DWN4
G1UP12
G1UP4
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN3
G2DWN3
G1UP11
G1UP3
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN2
G2DWN2
G1UP10
G1UP2
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN1
G2DWN1
G1UP9
G1UP1
R/W
R/W
R/W
R/W
R/W
R/W
G1DWN8
G1DWN0
G2DWN8
G2DWN0
G1UP8
G1UP0
Page 75
R/W
R/W
R/W
R/W
R/W
R/W

Related parts for gl846