tfs211c Vectron International, Inc., tfs211c Datasheet
tfs211c
Related parts for tfs211c
tfs211c Summary of contents
Page 1
... Remark: Reference level for the relative attenuation a rel of the TFS211C is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min is defined as the insertion loss The centre frequency the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss a e ...
Page 2
... VI TELEFILTER Construction and pin connection (All dimensions in mm TFS 211 C tft M04 test circuit L1 1:1 9 Input L3 50 Ohm TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application ...
Page 3
... VI TELEFILTER Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...
Page 4
... VI TELEFILTER Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...
Page 5
... VI TELEFILTER History Version Reason of Changes 2.0 generate detailled specification - add terminating impedances - add matching circuit - add tape and reel dimensions, stability characteristics and reflow profile VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice ...