tfs210e Vectron International, Inc., tfs210e Datasheet

no-image

tfs210e

Manufacturer Part Number
tfs210e
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
tfs210e.doc
______________________________________________________________________________________________________
VI
______________________________________________________________________________________________________
Measurement Condition
Ambient Temperature:
Input Power Level:
Source impedance:
Load impedance:
Terminating impedances:
Construction, pin connection and 50
see page 2
Stability characteristics and packing
see page 3
Air reflow temperature conditions
see page 4
Characteristics
Remark:
Reference level for the relative attenuation a rel is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min
is defined as the insertion loss a e . The nominal frequency f N is fixed to 210,38 MHz. The given values for the relative attenuation a rel and for the
phase ripple have to be reached at the frequencies given below also if the centre frequency f o is shifted due to the temperature coefficient of
frequency TC f in the operating temperature range and due to a production tolerance for the centre frequency f o .
D a t a
______________________________________________________________________________________________________
Insertion Loss
______________________________________________________________________________________________________
Nominal Frequency
______________________________________________________________________________________________________
5 dB - Bandwidth
______________________________________________________________________________________________________
Relative Attenuation
f N ± 0,63 MHz
f N ± 1,25 MHz ... f N ± 20 MHz
f N - 1,25 MHz
f N + 1,25 MHz
f N ± 2,05 MHz
______________________________________________________________________________________________________
Pass Band Ripple
______________________________________________________________________________________________________
Phase linearity
_____________________________________________________________________________________________________
Operating Temperature Range
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
(Reference level)
f N ± 0,300 MHz
input:
output:
TELEFILTER
f N ± 0,300 MHz
f N ± 0,630 MHz
630
915
23
50
50
a
f
BW
a rel
-
-
-
N
0 dBm
e
= a
C
single ended
single ended
|| -9.2 pF
|| -5.7pF
min
test circuit
Filter specification
45
45
40
typ. Value
8
1,6 MHz
0,3 dB
0,5 °rms
2,9 °rms
-
-
dB
-
dB
dB
dB
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
- 30 °C ... + 80 °C
TFS 210 E
version 1.4
max.
min.
max.
min.
min.
min.
max.
max.
max.
min.
210,38 MHz
Limit
10
35
35
37
1,26 MHz
5
1,2 dB
1,5 °rms
3,75 °rms
dB
dB
35 dB
dB
dB
dB
1/4
6/99

Related parts for tfs210e

tfs210e Summary of contents

Page 1

... VI TELEFILTER ______________________________________________________________________________________________________ Measurement Condition Ambient Temperature Input Power Level: 0 dBm Source impedance: 50 single ended Load impedance: 50 single ended Terminating impedances: input: 630 || -9.2 pF output: 915 || -5.7pF Construction, pin connection and 50 see page 2 Stability characteristics and packing see page 3 Air reflow temperature conditions ...

Page 2

... VI TELEFILTER ______________________________________________________________________________________________________ Construction and pin connection S 210 single ended test circuit L1 10 Input SAW 50 Ohm C1 1,2,3,5,6,7, 8,9,11,12 ______________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application ...

Page 3

... VI TELEFILTER ______________________________________________________________________________________________________ Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; DIN IEC Damp heat rel. humidity, 40 ° ...

Page 4

... VI TELEFILTER ______________________________________________________________________________________________________ Air Reflow Temperature Conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...

Related keywords