tfs210h Vectron International, Inc., tfs210h Datasheet

no-image

tfs210h

Manufacturer Part Number
tfs210h
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
TFS 210H.doc
VI TELEFILTER
Measurement condition
Ambient temperature T
Input power level:
Terminating impedances at f c *):
Characteristics
Remark:
the pass band attenuation a min is defined as the insertion loss a e The centre frequency f c is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss a e . The temperature coefficient of frequency Tc
reference frequency f c and the frequency response of the filter in the operating temperature range.
Data
Insertion Loss
(Reference level)
Centre Frequency at ambient temperature
Pass Band
Relative Attenuation
Group Delay Ripple in PB
Average Group Delay in PB
Operating Temperature Range
Storage Temperature Range
Turnover temperature T
Temperature Coefficient of frequency TC
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) q-values of matching inductors: q=40
***)
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
f c
f c  475
f c 
f c 
f c 
f c -
f c +
f c 
f(Hz) = TC f (ppm/K) x (T-T
tft@telefilter.com
Reference level for the relative attenuation a rel of the TFS 210H is the minimum of the pass band attenuation a min . The minimum of
2,0
1,175 MHz ......... f c 
1,3
1,475 MHz ......... f c 
2,0
5,0
kHz ......... f c  815
MHz ......... f c 
MHz ......... f c -
MHz ......... f c +
MHz ......... f c  10,0
.........
A
:
o
0
) x f To (MHz)
f c  475
23 C
0 dBm
input:
output:
1,3
1,475 MHz
2,0
5,0
5,0
f
***
1,17 k || -7,3 pF
1,06 k || -6,8 pF
f c
PB
a rel
MHz
MHz
MHz
MHz
MHz
a e
kHz
kHz
Filter Specification
version 1.1
225
- 0,036 ppm / K
24
38
43
48
45
52
15
typ. value
8,5
1,5
7
0,9
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
s
C
2
210,816 MHz
- 10 C ... + 55
- 40 C ... + 85
TFS 210H
max.
f c
max.
max.
min.
min.
min.
min.
min.
min.
max. 300
max.
tolerance / limit
11
50
10
20
30
40
45
42
40
f
is valid for both the
1,3 s
0,8 MHz
3
-
-
dB**
kHz
dB
dB
dB
dB
dB
dB
dB
dB
ns
C
C
07.01.2004
1/5

Related parts for tfs210h

tfs210h Summary of contents

Page 1

TFS 210H.doc VI TELEFILTER Measurement condition 23 C Ambient temperature Input power level: 0 dBm Terminating impedances *): input: output: Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 210H ...

Page 2

TFS 210H.doc VI TELEFILTER Package TFS 210H S02 50 matching network : L1 11 Input 50 Ohm C1 1,2,3,4,6,7,8,9,10,12 TELEFILTER GmbH Potsdamer Stra 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: ...

Page 3

TFS 210H.doc VI TELEFILTER Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration ...

Page 4

TFS 210H.doc VI TELEFILTER Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 C - 170 C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 80 60 ...

Page 5

TFS 210H.doc VI TELEFILTER History Version Reason of Changes 1.0 generate specification according to customer requirements 1.1 terminating impedance and typical values added TELEFILTER GmbH Potsdamer Stra 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: ...

Related keywords