tfs208c Vectron International, Inc., tfs208c Datasheet
tfs208c
Related parts for tfs208c
tfs208c Summary of contents
Page 1
... Tfs208C.doc VI TELEFILTER Measurement condition Ambient temperature ° Input power level: 0 Terminating impedances input: output: Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 208C is the maximum of the pass band attenuation a max . The maximum of the pass band attenuation a max is defined as the insertion loss The centre frequence the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss a e ...
Page 2
... Tfs208C.doc VI TELEFILTER Construction and pin connection (All dimensions in mm) 13.3 Max 13 TFS 208C 11 6 6.5 MAX. M46 Datecode 50 matching network Input SAW 50 Ohm C1 12 1,2,3,4,7,8,9,10 VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter ...
Page 3
... Tfs208C.doc VI TELEFILTER Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...
Page 4
... Tfs208C.doc VI TELEFILTER Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...
Page 5
... Tfs208C.doc VI TELEFILTER Version Reason of Changes 1.0 - generation of specification according to hudson specification 1.1 - correction according to customer specification (Nokia) - IP3: instead of ‘No statement’ VSWR (max): instead of - Rejection (f f 13000 KHz): instead of min Operational temperature range changed from -10 .... 80 ° -10 ..... 85 ° ...