tfs208h Vectron International, Inc., tfs208h Datasheet

no-image

tfs208h

Manufacturer Part Number
tfs208h
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
Tfs208h.doc
VI
Measurement Condition
Ambient temperature:
Input power level:
Source impedance:
Load impedance:
Terminating impedances: *)
Characteristics
Remark:
attenuation is the main time response lobe, the reference time is defined as t
The given values for the relative attenuation a rel and for the group delay ripple have to be reached at the frequencies given below even if the
centre frequency f c is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and due to a production
tolerance for the centre frequency f c .
D a t a
Absolute attenuation
Nominal frequency
Pass band ripple
f
f
f
1 dB-bandwidth
Relative attenuation
f
f
f
f
f
f
Echo response attenuation
t
t
t
t
t
Group delay
Group delay ripple
Input power level
VSWR
IP3 **)
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Frequency inversion temperature
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
**) f
***)
generated:
checked / approved:
______________________________________________________________________________________________________
TELEFILTER GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
N
N
N
N
N
N
N
N
N
0
0
0
0
0
+
+
+
+
+
-
+ 13
in,1
TELEFILTER
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
.....
13
=208MHz; f
f(Hz) = TC f (ppm/K) x (T-T
0,1 MHz ... f
0,2 MHz ... f
1,2 MHz ... f
1,8 MHz ... f
6
1
2
3
4
5
tft@telefilter.com
Reference level for the relative attenuation a rel of the TFS 208H is the attenuation at 208 MHz. Reference for the echo response
MHz ... f
MHz ... f
MHz ... f
s
s
s
s
s
in,2
... f
=208,1MHz; P
f
N
N
N
N
N
N
N
N
N
within f
within f
- 198 MHz
+ 242 MHz
within f
f
N
0,1 MHz
0,2 MHz
0,5 MHz
0,5 MHz
1,8 MHz
13 MHz
6 MHz
N
N
output:
0
) x f To (MHz)
N
in
input:
=4dBm+loss @f
0,5 MHz
200
0,5 MHz
23
50
0,1 MHz
a rel
a rel
at f
0 dBm
N
C
balanced
single ended
264
N
; f
// -12,7 pF
TC
T
out,1
0
Filter Specification
410
f
=207,9MHz; f
***
// -10,3 pF
out,2
=208,2MHz; then P
1180
525
100
0
. The nominal frequency f N is fixed at 208 MHz without tolerance.
15
28
50
65
65
35
45
55
70
80
65
18
15
typ. Value
-0,036 ppm/K
7
0,05 dB
0,1 dB
0,6 dB
-
-
-
-
dB
kHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
ns
ns
-
dB
dBm
C
out
2
<-56dBm
TFS 208 H
version 1.3
max.
max.
max.
min. 1000
max.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
max. 750
max. 150
max. + 10
max.
min.
- 10 C ... + 85 C
- 40 C ... + 125 C
6 ... 8,5 dB
208
Limit
25
35
50
50
20
30
40
40
50
60
0,25 dB
0,5 dB
1
9
2:1
1
-
-
MHz
dB
kHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
ns
ns
dBm
dBm
05.02.2003
1/5

Related parts for tfs208h

tfs208h Summary of contents

Page 1

... Tfs208h.doc VI TELEFILTER Measurement Condition Ambient temperature Input power level: 0 dBm Source impedance: 200 balanced Load impedance: 50 single ended Terminating impedances: *) input: output: 264 Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 208H is the attenuation at 208 MHz. Reference for the echo response ...

Page 2

... Tfs208h.doc VI TELEFILTER Construction and pin configuration (all dimensions in mm) TFS 208H matching circuit: input 200 balanced driven / output 50 LB- ______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Stra 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 tft@telefilter.com E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application ...

Page 3

... Tfs208h.doc VI TELEFILTER Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...

Page 4

... Tfs208h.doc VI TELEFILTER Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 C - 170 C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec ...

Page 5

... Tfs208h.doc VI TELEFILTER History Version Reason of Changes Development specification 1.0 generation of development specification 1.1 terminating impedance (preliminary values) and typical values of relative attenuation Pfeiffer added 1.2 1 dB-bandwidth added 1.3 terminating impedance and typical values of relative attenuation changed ______________________________________________________________________________________________________ TELEFILTER GmbH Potsdamer Stra 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 tft@telefilter ...

Related keywords