tfs280g Vectron International, Inc., tfs280g Datasheet

no-image

tfs280g

Manufacturer Part Number
tfs280g
Description
Vi Telefilter Filter
Manufacturer
Vectron International, Inc.
Datasheet
Filename: tfs280g.doc
VI
Measurement condition
Ambient temperature:
Input power level:
Source and load impedance:
Terminating impedances *
Characteristics
Remark:
The reference level for the relative attenuation a rel of TFS280G is the minimum of the pass band attenuation a min . This value is defined as the
insertion loss a e . The centre frequency f c is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss a e . The given values for the relative attenuation a rel and the group delay ripple have to be reached at the frequencies
given below, even if the centre frequency f c is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and
due to a production tolerance for the centre frequency f c .
D a t a
Insertion loss
Nominal frequency
Centre frequency
Relative attenuation
f
f
f
Group delay ripple
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Generated:
Checked / approved:
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
N
N
N
**)
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
-
+
+
TELEFILTER
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
f(Hz) = TC f (ppm/K) x (T-T
20
10
32
40
f
tft@telefilter.com
N
Input:
Output:
 17 MHz ... f
MHz ... f
MHz ... f
MHz ... f
MHz ... f
GDR
N
N
N
N
N
+
-
+
+ 220
+ 17 MHz
a e = a min
f N
f c
a rel
0
) x f To (MHz)
20
32
40
MHz
MHz
MHz
MHz
22
50
275
162
0
2
|| -7,7 pF
|| -10,6 pF
dBm
C
Filter specification
TCf
typ. value
280,0
-87
11,3
41
38
41
38
0,8
-
-
-
-
version 1.6
dB
MHz
dB
dB
dB
dB
ns
ppm/K
TFS 280 G
max.
max.
min.
min.
min.
max.
max. + 10
- 40 C ... + 85 C
- 40 C ... + 85 C
limit
280,0 MHz
12
40
37
40
75
1
-
-
16.10.2003
dB
dB
dB
dB
dB
ns
dBm
1/5

Related parts for tfs280g

tfs280g Summary of contents

Page 1

... Remark: The reference level for the relative attenuation a rel of TFS280G is the minimum of the pass band attenuation a min . This value is defined as the insertion loss The centre frequency the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a e ...

Page 2

... Filename: tfs280g.doc VI TELEFILTER Construction and pin connection (All dimensions in mm 280 G R16 1 3 Date code 1 Input RF return 2 Input 3 Ground 4 Ground 5 Output RF return 6 Output 7 Ground 8 Ground 50 test circuit L1 2 Input 50 Ohm SAW C1 1,3,4,5,7,8 Tele Filter GmbH Potsdamer Stra 513 TELTOW / Germany ...

Page 3

... Filename: tfs280g.doc VI TELEFILTER Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC Vibration 500 Hz, 0, respectively, 1 octave per min, 10 cycles per plan, 3 plans; ...

Page 4

... Filename: tfs280g.doc VI TELEFILTER Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 C - 170 C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec ...

Page 5

... Filename: tfs280g.doc VI TELEFILTER History Version Reason of Changes 1.0 - new generation 1.1 - change temperature, add 3dB passband requirement - relax stop-band limit lines according to larger temperature range 1.2 - source and load impedance added - passband magnitude extended to +/-20MHz - Tk added 1.3 - label changed to standard label 1.4 - change pinning corresponding to customer demands ...

Related keywords