tfs270a1 Vectron International, Inc., tfs270a1 Datasheet
tfs270a1
Related parts for tfs270a1
tfs270a1 Summary of contents
Page 1
... TFS270A1.doc __________________________________________________________________________________________________________ VI TELEFILTER __________________________________________________________________________________________________________ Measurement condition Ambient temperature Input power level: 0 dBm Terminating impedance input: Terminating impedance output: 510 || -1.75 pF ext. coil pin4 Construction see page 2 Characteristics Remark: Reference level for the relative attenuation a rel of the TFS 270A1 is the minimum of the pass band attenuation a min . The minimum of the pass band attenuation a min is defined as the insertion loss a e ...
Page 2
... TFS270A1.doc __________________________________________________________________________________________________________ VI TELEFILTER __________________________________________________________________________________________________________ Construction and pin configuration (All dimensions in mm) 1 Output 3 Ground 5 Ground 6 Ground 7 Input 9 Ground 10 Ground 11 Ground 12 Ground 50 Ohm Test circuit 1 L1 LB- Ohm Test circuit 2 C1 LB-IN C3 __________________________________________________________________________________________________________ VI TELEFILTER Potsdamer Straß 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter ...
Page 3
... TFS270A1.doc __________________________________________________________________________________________________________ VI TELEFILTER __________________________________________________________________________________________________________ Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 100g, 18 ms, half sine wave, 3 shocks each plane; IEC Vibration 500 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; IEC Damp heat rel. humidity, 40 ° ...
Page 4
... TFS270A1.doc __________________________________________________________________________________________________________ VI TELEFILTER __________________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods Temperature: 150 °C - 170 °C Time: 60 sec sec. 260 240 220 200 180 160 140 120 100 Table for temperature vs. time during the air reflow process time / sec. temperature / ° ...