RP10-4805SEWM2 RECOM [Recom International Power], RP10-4805SEWM2 Datasheet

no-image

RP10-4805SEWM2

Manufacturer Part Number
RP10-4805SEWM2
Description
Manufacturer
RECOM [Recom International Power]
Datasheet
Selection Guide
Part Number
RP10-2405SEW
RP10-2412SEW
RP10-2415SEW
RP10-4805SEW
RP10-4812SEW
RP10-4815SEW
RP10-2405DEW
RP10-2412DEW
RP10-2415DEW
RP10-4805DEW
RP10-4812DEW
RP10-4815DEW
224
* add suffix /M M 2 for higher efficiencies and extended temperature range.
* add /P P for CTRL function with Positive Logic (1=ON, 0=OFF)
* add /N N for CTRL function with Negative Logic (0=ON, 1=OFF)
Features
24V and 48V Input Types
Range
18-75
18-75
18-75
18-75
18-75
18-75
Input
9-36
9-36
9-36
9-36
9-36
9-36
VDC
Voltage
4:1 Wide Input Voltage Range
10 Watts Output Power
1.6kVDC Isolation
Fixed Operating Frequency
Six-Sided Continuous Shield
Standard 50.8 x25.4x10.2mm Package
Efficiency to 84%
Output
VDC
±12
±15
±12
±15
±5
±5
12
15
12
15
5
5
Current
±1000
±1000
Output
±416
±333
±416
±333
2000
2000
830
670
830
670
mA
Input
Current
548
532
551
274
259
262
548
547
548
271
281
270
mA
July-2006
(4)
Efficiency
80
82
80
80
84
84
80
80
80
81
78
81
%
(5)
Capacitive
Load max.
4700
4700
±680
±330
±110
±680
±330
±110
690
470
690
470
µF
(6)
POWERLINE
DC/DC-Converter
RP10-
S_DEW
Series
10 Watt
2” x 1” Package
Single
Output
www.recom-international.com
&
Dual

Related parts for RP10-4805SEWM2

RP10-4805SEWM2 Summary of contents

Page 1

... RP10-4815SEW 18-75 15 RP10-2405DEW 9-36 ±5 RP10-2412DEW 9-36 ±12 RP10-2415DEW 9-36 ±15 RP10-4805DEW 18-75 ±5 RP10-4812DEW 18-75 ±12 RP10-4815DEW 18-75 ±15 * add suffix / for higher efficiencies and extended temperature range. * add /P P for CTRL function with Positive Logic (1=ON, 0=OFF) * add /N N for CTRL function with Negative Logic (0=ON, 1=OFF) ...

Page 2

... RP10-S_DEW Series (Ambient Temperature) RP10-2405SEW With Heat Sink Natural Convection RP10-2405DEW With Heat Sink Natural Convection RP10-2405SEW/M2 With Heat Sink Natural Convection RP10-2405DEW/M2 With Heat Sink Natural Convection July-2006 ...

Page 3

... Isolation Capacitance Operating Frequency Operating Temperature Range (Reference Derating Curve) (see Note 9) Maximum Case Temperature Storage Temperature Range Thermal Impedance (see Note 8) Thermal Shock 226 RP10-S_DEW Series 24V nominal input 48V nominal input 24V Input 48V Input DC-DC ON DC-DC OFF DC-DC ON DC-DC OFF Nominal input ...

Page 4

... MTBF (see Note 2) Notes : 1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listedspecification. 2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment). ...

Page 5

... POWERLINE DC/DC-Converter Package Style and Pinning (mm) Bottom View 228 RP10-S_DEW Series Pin Connections Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* * Optional. See Note 7 Pin Pitch Tolerance ±0.35 mm July-2006 www.recom-international.com Dual +Vin -Vin +Vout Com -Vout CTRL* ...

Related keywords