g4a-1a-pe Omron Corporation, g4a-1a-pe Datasheet
g4a-1a-pe
Available stocks
Related parts for g4a-1a-pe
g4a-1a-pe Summary of contents
Page 1
... Max. permissible voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. 150 Contact Form SPST-NO Rated coil voltage 4. Special Function E: 5. Rated Coil Voltage 5, 12, 24 VDC 12 VDC 75 mA 160Ω 0.8 H 1.1 H Model G4A-1A-E G4A-1A-PE For long endurance 24 VDC 37.5 mA 640Ω 3 ...
Page 2
... PCB Power Relay – G4A ■ Contact Ratings Rated load 250 VAC Rated carry current 20 A Max. switching voltage 250 VAC Max. switching current 20 A Max. switching power 5,000 VA Failure rate (ref. value) 100 VDC Note: P level: λ 0 /operation (with an operating frequency of 120 operations/min) ...
Page 3
... PCB Power Relay – G4A DIN EN 61810-1/EN 60255-23 (VDE Reg. No. 6673) Model G4A-1A Engineering Data Maximum Switching Power AC inductive load cosφ = 0.4 Switching voltage (V) 152 Coil ratings VDC Endurance 5,000 3,000 AC resistive load 1,000 700 500 300 100 70 50 Contact ratings ...
Page 4
... PCB Power Relay – G4A Dimensions Note: All units are in millimeters unless otherwise indicated; dimensions shown in parentheses are in inches. G4A-1A-E G4A-1A-PE Precautions Mounting When mounting two or more relays side by side, provide a minimum space between relays. Terminal Connection The terminals fit FASTON receptacle 250 and are suitable for positive-lock mounting. ...