kaqv210ab ETC-unknow, kaqv210ab Datasheet

no-image

kaqv210ab

Manufacturer Part Number
kaqv210ab
Description
High Voltage, Photo Relay
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KAQV210AB
Manufacturer:
COSMO
Quantity:
260
DB LECTRO Inc.
Features
1. Normally Open, Single Pole Single Throw
2. Control 350VAC or DC Voltage
3. Switch 130mA Loads
4. LED control Current, 5mA
5. Low ON-Resistance
6. dv/dt, >500V/ms
7. Isolation Test Voltage, 3750VACrms
Absolute Maximum Ratings
Electro-optical Characteristics
Mos Relay Schematic and Wiring Diagrams
KAQV210AB
KAQV210B
General Characteristics
Isolation Test Voltage……………3750VACrms
Isolation Resistance
Vio=500V, Ta=25°C …………………… 10
Total Power Dissipation ………………550mW
Derate Linearly from 25°C …………2.5mW/°C
Emitter ( Input )
Reverse Voltage……………………………5.0V
Continuous Forward Current ……………50mA
Peak Forward Current ………………………1A
Power Dissipation ……………………100mW
Derate Linearly from 25°C …………1.3mW/°C
Parameter
Emitter (Input)
Forward Voltage
Operation Input Current
Recovery Input Current
Detector (Output)
Output Breakdown Voltage
Output Off-State Leakage
I/O Capacitance
ON Resistance
Turn-On Time
Turn-Off Time
Type
&
Schematic
Connection
configuration
Output
1a
High Voltage, Photo Mos Relay
A
B
C
10
Detector ( Output )
Output Breakdown Voltage ……………±350V
Continuous Load Current ……………±130mA
Power Dissipation ……………………500mW
Storage Temperature Range …-40°C to +125°C
Operating Temperature Range…-30°C to +85°C
Junction Temperature……………………100°C
Soldering Temperature,
2mm from case, 10 sec …………………260°C
AC/DC
Load
DC
DC
Symbol
I
I
C
T
I
R
FOFF
TOFF
T
FON
V
V
OFF
ISO
ON
ON
F
B
Connection
C
A
B
V
L
=±20V, I
I
t =10ms, I
I
L
F
V
V
=100mA, I
T
=10mA, V
E
D
L
I
F
=100V, I
=±20V, I
Conditions
=0, f =1MH
UL 1577/ UL 508 (File No.E108430), FI EN60950 (File No.FI13698)
I
L
I
F
B
=100mA, t =10mS
=10mA
=50uA
L
(Ta=25°C)
=±100mA
F
F
L
L
=0mA
=10mA
=±20V
5uA
Z
KAQV210B/210AB
Wiring Diagrams
0.05
Min.
350
Typ.
1.2
0.2
0.1
0.3
28
14
6
7
Turn on/ Turn off time
TOLERANCE :
TOLERANCE :
Max.
1.5
0.5
0.5
35
18
5
2
9
Unit : mm
Unit : mm
(Ta=25°C)
KAQV210AB
KAQV210B
±
±
0.2mm
0.2mm
Unit
mA
mA
ms
ms
uA
pF
V
V

Related parts for kaqv210ab

kaqv210ab Summary of contents

Page 1

... OFF L Load Connection AC/ KAQV210B/210AB TOLERANCE : TOLERANCE : Turn on/ Turn off time Min. Typ. Max. 1.2 1.5 5 5uA 0.05 350 =0mA 0 =10mA =±20V 0.1 0.5 0.3 0.5 Wiring Diagrams KAQV210B Unit : mm ± 0.2mm KAQV210AB Unit : mm ± 0.2mm (Ta=25°C) Unit ...

Page 2

DB LECTRO Inc. Data Curve Fig.1 Load current vs. ambient temperature Allowable ambient temperature: -40°C to +85°C Ambient Temperature Ta (°C) Fig.4 Turn off time vs. ambient temperature LED current: 5mA; Load voltage: 350V(DC) Continuous load current: 130mA(DC) Ambient Temperature ...

Related keywords