cl02jt10n Viking Tech Corporation, cl02jt10n Datasheet - Page 4

no-image

cl02jt10n

Manufacturer Part Number
cl02jt10n
Description
Multilayer Chip Inductor?
Manufacturer
Viking Tech Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CL02JT10N
Manufacturer:
VIKING/光颉
Quantity:
20 000
■ ■ ■ ■
82
Climatic Test
Paper Tape Specifications
Reel Dimensions
Thermal Shock
High Humidity State Life
High Humidity Load Life
High Temperature State Life
High Temperature Load
Storage Temperature: 25±3° ° ° ° C; Humidity < 80%RH
Packaging
Type
CL02
CL03
CL02
CL03
Type
W±0.2
F±0.05
Item
178±1
178±1
0.65
1.10
A
A
4±0.1
Tel:886-3-5972931
P±0.1
60.2±0.5
60.0+0.5
1.12
1.80
No visible damage
Inductance variation within 10%
Q variation within 20%
No visible damage
Inductance variation within 10%
Q variation within 20%
No visible damage
Inductance variation within 10%
Q variation within 20%
No visible damage
Inductance variation within 10%
Q variation within 20%
No visible damage
Inductance variation within 10%
Q variation within 20%
B
B
A±0.1
2±0.05
13.0±0.20
13.0±0.20
0.60
0.95
T
C
Requirement
Fax: 886-3-5973494
1.75±0.1
B±0.1
W
9.00±0.5
9.00±0.5
8
8
W
T±0.05
P
12.0±0.15
12.0±0.15
2
4
T
Solder a test sample to printed circuit board, and conduct 100
cycles of test under the conditions shown as below.
Cycle:
100°C/1hr
Keep a test sample in an atmosphere with a temperature of
70±2° C, 90~95%RH for 500±12 hours. After the test, keep the
test sample at a normal temperature for 1 to 2 hours, and then
carry out measurement.
Solder a test sample to printed circuit board then keep the test
sample in an atmosphere with a temperature of 70±2°C,
90~95%RH for 500±12 hours while supplying the rated current.
After the test, keep the test sample at a normal temperature for 1
to 2 hours, and then carry out measurement.
Keep a test sample in an atmosphere with a temperature of
100±2° C for 500±12 hours. After the test, keep the test sample
at a normal temperature for 1 to 2 hours, and then carry out
measurement.
Solder a test sample to printed circuit board then keep the test
sample in an atmosphere with a temperature of 100±2° C for
500±12 hours while supplying the rated current. After the test,
keep the test sample at a normal temperature for 1 to 2 hours,
and then carry out measurement.
3.5
3.5
E-mail:
F
Quantity (EA)
10,000
4,000
Unit: mm
sales@viking.com.tw
Unit: mm
K
Test Condition
Within 2min.
http://www.viking.com.tw
-40° C/1hr

Related parts for cl02jt10n