NC12S0A0V60NNFA DELTA [Delta Electronics, Inc.], NC12S0A0V60NNFA Datasheet

no-image

NC12S0A0V60NNFA

Manufacturer Part Number
NC12S0A0V60NNFA
Description
Delphi NC Series Non-Isolated Point of Load DC/DC Power Modules: 12Vin, 0.9V-5Vout, 60A
Manufacturer
DELTA [Delta Electronics, Inc.]
Datasheet
Delphi NC Series Non-Isolated Point of Load
DC/DC Power Modules: 12Vin, 0.9V-5Vout, 60A
The Delphi NC Series, 12V input, single output, non-isolated point of
load DC/DC converters are the latest offering from a world leader in
power systems technology and manufacturing ― Delta Electronics,
Inc. This product family provides up to 60A of power in a vertical or
horizontal mounted through-hole package. The NC12S0A0V60 will
provide up to 60A of output current and the output can be resistor- or
voltage-trimmed from 0.9Vdc to 5.0Vdc. It provides a very cost
effective point of load solution. With creative design technology and
optimization of component placement, these converters possess
outstanding electrical and thermal performance, as well as extremely
high reliability under highly stressful operating conditions.
DATASHEET
DS_NC12S60A_02072007
OPTIONS
FEATURES
APPLICATIONS
Negative On/Off logic
0.9Vdc to 5.0Vdc via external resistors
OHSAS 18001 certified manufacturing
facility
and TUV (EN60950) Certified
directives
High Efficiency:
Voltage and resistor-based trim
No minimum load required
Output voltage programmable from
Fixed frequency operation
Input UVLO, output OTP, OCP, SCP
Remote ON/OFF (default: positive)
ISO 9001, TL 9000, ISO 14001, QS9000,
UL/cUL 60950 (US & Canada) Recognized,
CE mark meets 73/23/EEC and 93/68/EEC
95% @ 12Vin, 5V/60A out
DataCom
Distributed power architectures
Servers and workstations
LAN/WAN applications
Data processing applications

Related parts for NC12S0A0V60NNFA

NC12S0A0V60NNFA Summary of contents

Page 1

Delphi NC Series Non-Isolated Point of Load DC/DC Power Modules: 12Vin, 0.9V-5Vout, 60A The Delphi NC Series, 12V input, single output, non-isolated point of load DC/DC converters are the latest offering from a world leader in power systems technology and ...

Page 2

TECHNICAL SPECIFICATIONS PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage Operating Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter ...

Page 3

ELECTRICAL CHARACTERISTICS CURVES 100 Output Current (A) Figure 1: Converter efficiency vs. output current (0.9V output voltage) 100 ...

Page 4

ELECTRICAL CHARACTERISTICS CURVES (CON.) 100 Output Current (A) Figure 7: Converter efficiency vs. output current (5V output voltage) Figure 9: Output ripple & noise at 12Vin, ...

Page 5

ELECTRICAL CHARACTERISTICS CURVES (CON.) Figure 13: Output ripple & noise at 12Vin, 3.3V/60A out Figure 15: Turn on delay time at 12Vin, 0.9V/60A out Ch1:OUTEN Ch2:Vout Ch3:PWRGD Figure 17: Turn on delay time at 12Vin, 3.3V/60A out Ch1:OUTEN Ch2:Vout Ch3:PWRGD ...

Page 6

ELECTRICAL CHARACTERISTICS CURVES (CON.) Figure 19: Typical transient response to step load change at 10A/µS from 50% to 75% and 75% to 50% of Io, max at 12Vin, 1.2V out Figure 21: Typical transient response to step load change at ...

Page 7

DESIGN CONSIDERATIONS The NC60A is designed using three-phase synchronous buck topology. Block diagram of the converter is shown in Figure 25. The output can be trimmed in the range of 0. resistor from trim pin to ...

Page 8

FEATURES DESCRIPTIONS (CON.) o VIN o GROUND TRIM OUTEN GROUND Figure 28: Remote ON/OFF Input Drive Circuit Remote Sense Remote sense compensates for voltage drops on the output by sensing the actual output voltage at the point of load. The ...

Page 9

FEATURES DESCRIPTIONS (CON.) NC60A Vout Cout +SENSE -SENSE GROUND I-SHARE TRIM NC60A 0 Cout Vout +SENSE -SENSE GROUND I-SHARE TRIM Figure 30: NC60A Current Share Diagram Output Voltage Programming The output on the module is trimmable by connecting an external ...

Page 10

Voltage Margin Adjusting Output voltage margin adjusting can be implemented in the NC60A modules by connecting a resistor, R from the Trim pin to the ground pin for adjusting voltage a little bit higher. Also, the output voltage can be ...

Page 11

THERMAL CURVES (NC12S0A0V60) Figure 36: Temperature measurement location * The allowed maximum hot spot temperature is defined at 127 NC12S0A0V60 (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vout =5V (Either Orientation) Output Current ( ...

Page 12

MECHANICAL DRAWING DS_NC12S60A_02072007 VERTICAL 12 ...

Page 13

PART NUMBERING SYSTEM Product Input Number of Series Voltage outputs NC- 12- S- Single 0A0- Non-isolated 11.04~12.6V output programmable Converter MODEL LIST Model Name Packaging NC12S0A0V60PNFA Vertical CONTACT: www.delta.com.tw/dcdc USA: Telephone: East Coast: (888) 335 8201 West ...

Related keywords