MPQ24S24-50 WALL [Wall Industries,Inc.], MPQ24S24-50 Datasheet

no-image

MPQ24S24-50

Manufacturer Part Number
MPQ24S24-50
Description
50 W DC-DC Converter 10-36 Vdc Input 24 Vdc Output at 2.5 A Quarter-Brick Package
Manufacturer
WALL [Wall Industries,Inc.]
Datasheet
Features:
• Over 88% Efficient at Full Load
• Fast Transient Response
• Operation to No Load
• Output Trim +/-10%
• Remote ON/OFF
• Remote Sense Compensation
• Low Output Ripple
Description:
The MPQ24 series is a high density, low voltage input quarter brick converter that incorporates the
desired features required in today’s demanding applications while maintaining low cost.
performance, reliability, and low cost are needed, the MPQ series delivers.
(888) 597-WALL
MPQ24S24-50
Quarter-Brick Package
50 W DC-DC Converter
24 Vdc Output at 2.5 A
10-36 Vdc Input
www.wallindustries.com
• Fixed Switching Frequency
• Output Over Current Protection
• Output Short Circuit Protection
• Over Temperature Protection
• 1000 V Isolation
• 100% Burn In
• Heatsink Available
TECHNICAL DATASHEET
1 of 11
When
Rev. A

Related parts for MPQ24S24-50

MPQ24S24-50 Summary of contents

Page 1

... MPQ24S24-50 Features: • Over 88% Efficient at Full Load • Fast Transient Response • Operation to No Load • Output Trim +/-10% • Remote ON/OFF • Remote Sense Compensation • Low Output Ripple Description: The MPQ24 series is a high density, low voltage input quarter brick converter that incorporates the desired features required in today’ ...

Page 2

... Io, di/dt=0.025A/uS Recovery to within 1% Nominal Vout From Vin(min) to Vout (nom) Full Load Resistive From Vin (min ULVO_Turn_Off Active High or Active Low (Add an ‘R’ to the end of the PN ie: MPQ24S24-50R) Min High to Enable Max Low to Disable Over Operating Voltage Range V =0V, Vin=36 V ...

Page 3

... SEE NOTE-4 .005 .00 [0.0] C .071± .005 [1.80± 0.13] STANDOFF DIMENSION Ø.040 [1.02] PINS ONLY 4X RECOMMENDED FINISHED RECEIVING PCB 2.00 [50.8] STAND-OFF HOLE Ø.052± .003 [1.32± 0.08] PIN-2 SHOWN FOR DIMENSIONS www.wallindustries.com TECHNICAL DATASHEET MPQ24S24-50 Comments .00 [0. WALL INDUSTRIES 8 8 ...

Page 4

... Lastly, as the case/heatsink is floating metal, caution must also be observed to provide appropriate spacing (minimum 1.4 mm for Pollution degree 2 Material Group IIIa + IIIb) around the case/heatsink or risk reducing the input to output spacing and violating Basic insulation requirements. (888) 597-WALL TECHNICAL DATASHEET Rev. A www.wallindustries.com MPQ24S24-50 Page ...

Page 5

... High 863.49 remains the same, and while increasing the output voltage, the output current is 433.49 reduced to maintain the total output power 290.16 218.49 175.49 146.82 126.35 110.99 99.05 89.49 www.wallindustries.com TECHNICAL DATASHEET MPQ24S24- ⋅ ∆ 100 100 − − (in k ∆ ⋅ ...

Page 6

... Divide this power by the desired trimmed high voltage to get the maximum current at that ambient. When trimming low, the maximum current stays the same as shown in Graph 2. (888) 597-WALL Rev. A Graph 1: MPQ24S24-50 Efficiency vs. Output Current 1.0 1.5 I (A) o Graph 2: MPQ24S24-50 Max Ambient vs ...

Page 7

... WALL INDUSTRIES, INC. Graph 3: MPQ24S24-50 Input Current vs. Input Voltage 6.0 5.0 4.0 3.0 2.0 1.0 0 (V) in Graph 5: MPQ24S24-50 No Load Input Current and Power Dissipation vs. Input Voltage 0.150 Input Current 0.125 Power Dissipation 0.100 0.075 0.050 0.025 0.000 (V) in Note 4: Voltage measurements taken where the output pins are soldered into test board ...

Page 8

... WALL INDUSTRIES, INC. Graph 7: MPQ24S24-50 Load Regulation (+SENSE to +Vout, -SENSE to -Vout) 0.05% 0.04% 0.03% 0.02% 0.01% 0.00% -0.01% -0.02% -0.03% -0.04% -0.05% 0.0 0.2 0 Graph 9: MPQ24S24-50 Output Temperature Drift (+SENSE to +Vout, -SENSE to -Vout) 1.0% 0.8% 0.5% 0.3% 0.0% -0.3% -0.5% -0.8% -1.0% -40 - Case Temperature (°C) (888) 597-WALL Rev. A Vin=12V Vin=20V Vin=28V Vin=36V -0.01% -0.02% -0.03% -0.04% -0.05% 0.6 0.8 1.0 ( www.wallindustries.com TECHNICAL DATASHEET MPQ24S24-50 Graph 8: MPQ24S24-50 Line Regulation (+SENSE to +Vout, -SENSE to -Vout) 0 ...

Page 9

... Photo 5: Turn On by Enable Cout = 68 uF (888) 597-WALL TECHNICAL DATASHEET Rev. A Photo 2: Input Ripple Voltage and Current Vin=24 V, Iout = 2.5 A With a 120 uF Aluminum Electrolytic across the Input Photo 4: Normal Turn Off Cout = 68 uF Photo 6: Turn Off by Enable Cout = 68 uF www.wallindustries.com MPQ24S24-50 Page ...

Page 10

... With Electrolytic across the Output Photo 10: Transient Response – 0.025A/us Vin=24 V, Iout = 0.625 to 1.875 A (25% to 75%) With Electrolytic across the Output Photo 12: Transient Response – 0.1A/us Vin=24 V, Iout = 0.625 to 1.875 A (25% to 75%) With Electrolytic across the Output www.wallindustries.com MPQ24S24-50 Page ...

Page 11

... Input Voltage Single Output Nominal Output Voltage Options R C Phone: (603)778-2300 Toll Free: (888)587-9255 Fax: (603)778-9797 E-mail: sales@wallindustries.com Web: www.wallindustries.com Address: 5 Watson Brook Rd. Exeter, NH 03833 www.wallindustries.com TECHNICAL DATASHEET MPQ24S24-50 Maximum Output Power Leave Blank for no Options Active Low Heatsink/Case Page ...